3H3
1-5-9
1-5-2 Centerfold unit
(1) Detaching and refitting the centerfold blade
Follow the below procedure to clean or replace the centerfold blade.
Procedure
1. Pull out the centerfold unit from the finisher.
2. Loosen the two screws, slide the retainers in
the direction of the arrow, and remove the
centerfold unit from the finisher.
Figure 1-5-18
3. Stand the centerfold unit with its left side fac-
ing down.
4. Remove the six screws locking down the left
base followed by the base.
Figure 1-5-19
5. Disconnect the 2-pin connector of the blade
motor.
6. Remove the two screws and then remove
the blade motor.
Figure 1-5-20
Centerfold unit
Retainer
Screw
Screw
Retainer
Centerfold unit
Left base
2-pin connector
Blade drive belt
Blade motor
Y1043
71-8
Service Manual