9. If the stapler adjustment metal is not
inserted into the adjustment hole, loosen the
four adjustment screws on the intermediate
tray and adjust the stapler unit mounting
position so that the metal is inserted into the
hole.
At this time, turn the gear manually further-
more and ensure that the stapler is securely
pushed into the inner part.
10. Tighten the adjustment screws in the order
shown below.
1) Tighten the upper two screws loosely.
2) Tighten the lower two screws loosely.
3) Finally tighten the upper two screws.
4) Finally tighten the lower two screws.
Figure 1-5-13
11. Turn the gear manually to pull back the sta-
pler to its original position and then remove
the cartridge adjustment tool.
12. Remove the stapler adjustment metal and
the stapler adjustment tool.
13. With the stapler cartridge removed, return
the intermediate tray to its original position
and mount the finisher to the machine. Turn
the machine main power switch on (to
detect the noncartridge status).
14. Pull out the intermediate tray again and
attach the stapler cartridge. Mount the fin-
isher to the machine and turn the main
power switch on.
15. Select the staple mode (mode specifying the
stapler that has been adjusted) and carry
out this mode.
After the staples in the cartridge are auto-
matically fed in test stapling, the staple
mode will be carried out.
16. Check the shape of the staples on the rear
side that have been used in the test stapling
and the staple mode above.
If the shape is defective, perform the adjust-
ment again.
Adjustment screws
Intermediate tray
Adjustment screws
Normal
Defective
Shape of staples on the rear side
a
a 0.5mm
a 0.5mm
a
Service Manual Y1043
71
-
8