Page: 47
Service Guide OL600e/610e/610ePS
Chapter 3 Parts Replacement
3.3.13 Fusing Unit Assy
(1) Remove the upper cover (see 3.3.1).
(2) Remove the stacker cover assy (see 3.3.10).
(3) Remove four screws 1 and remove the fusing unit 2.
Caution:
Fusing unit assy may be hot. Use care when handling.
Notes:
When installing or removing the fusing unit assy, tighten or loosen the screws while holding the
fusing unit down with your hand. When reinstalling screws 1 , be sure to direct the screws into the
pre-existing hole to avoid damaging the threads. Do not apply excessive torque when tightening the
screws 1; if these screws are stripped, the entire lower unit assembly must be replaced. • When
reinstalling the fuser, insert the left side first, then lower the right side into place.
Summary of Contents for OL600e