![OKIDATA ML393C Plus Service Manual Download Page 98](http://html1.mh-extra.com/html/okidata/ml393c-plus/ml393c-plus_service-manual_729925098.webp)
Page: 65
Service Guide ML393/ML393CPlus
Chapter 3 Maintenance
3.2.13 Ribbon Feed Assembly
1. Remove the upper cover assembly
(3.2.04
).
2. Remove the printer mechanism
(3.2.08
).
3. Remove the left shoulder screw [color] (1A) and right should screw [color] (1B).
4. Detach the cartridge bracket (2).
5. Remove the two mounting screws (3).
6. Detach the ribbon feed assembly (4).
NOTE:
When assembling, install the ribbon drive assembly so that the gear teeth contact properly (5). The gears
must not bind together.
The ribbon cartridge balance spring is NOT shown. Refer to Appendix B of this Service Handbook for
further information.
P/N 50312103 Screw: Shoulder Left (Color) RSPL B.2.10
P/N 50312106 Screw: Shoulder Right (Color) RSPL B.2.10
P/N N/A Cartridge Bracket
P/N 50054301 Assembly: Ribbon Feed RSPL B.2.07
, B.2.10