Chapter 2 Principles of Operation
2.1.04 Interface Control
Parallel Interface
The data from the interface is received through connector (CN-1) and the Interface LSI (Q7) latches this
data in sync with the STB signal.
The BUSY signal is switched ON as the data is processed. When processing is completed, the BUSY
signal is switched OFF and an ACK signal is sent to the host to request more data.
The BUSY signal is also switched ON when the printer is not able to receive data (buffer is full, printer is
deselected or an error condition exists).
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)