![background image](http://html1.mh-extra.com/html/okidata/610e/610e_service-manual_729893098.webp)
Troubleshooting
6 - 5
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602
Category
Status message
Trouble or status
Remedy
Controller errors
Note:
On the
OL600e and
OL610e, control-
ler errors are
described, not
listed by Excep-
tion code.
Table 6-1 (Cont'd)
Code
Error
(nn)
Remedy
Replace the Main Control PCB.
Replace the Main Control PCB.
Replace the Main Control PCB.
Replace the Main Control PCB.
– Replace the EEPROM or Main Control PCB.
– EEPROM
Check the optional ROM board for proper con-
nection or replace it.
0n
A fault occurred in the controller.
n = Exception Code
10
An error was detected by program
ROM check.
20
An error was detected by font ROM
check.
30
An error was detected by resident
RAM check.
40
An error was detected by EEPROM
check.
50
An error was detected by optional
software ROM check.
ERROR nn