Adjustment
4 - 5
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602
Setting
Example: Method for setting the parameter to 19 (for case where the previous parameter
setting was 21).
OL610e/PS
LCD display after operation
Turn the POWER switch
on while holding the
FORM FEED and ENTER
keys down.
Press + or - key, until "19"
is displayed.
Press the ENTER key.
Turn the POWER switch on
while pressing the FORM
FEED and ENTER keys.
Operation
Displays previous
parameter No.
Parameter 19 is
set to EEPROM
(* is displayed on
LCD).
ENG MNT
LED HEAD
No. 21 *
LED HEAD
No. 19
LED HEAD
No. 19 *
OL600e, OL610e
1.
At the DOS prompt, enter OL600 /S, then click on Service tab.
2.
On the Head Drive Time listbox, click the up arrow until 19 shows in the box.
3.
Click OK.