![background image](http://html1.mh-extra.com/html/okidata/610e/610e_service-manual_729893126.webp)
Troubleshooting
6 - 33
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602
5
Cyclic Error
Frequency
Remedy
Image drum
3.71” (94.2 mm)
Replace or clean the image drum cartridge.
Developing roller
1.66” (44.4 mm)
Replace the image drum cartridge.
Toner supply roller
2.27” (57.8 mm)
Replace the image drum cartridge.
Charging roller
1.56” (39.6 mm)
Replace the image drum cartridge.
Cleaning roller
1.24” (31.4 mm)
Replace the image drum cartridge.
Transfer roller
2.01” (51.0 mm)
Replace the transfer roller.
Heat roller
2.47” (62.8 mm)
Replace the fusing unit assy.
Back-up roller
2.72” (69.08 mm)
Replace the back-up roller.
Notes:
1.
After replacing the image drum cartridge, reset the drum counter.
2
After replacing the fusing unit assy, reset the fuser counter.
OL610e/PS: See 4.1.