![background image](http://html1.mh-extra.com/html/okidata/610e/610e_service-manual_729893066.webp)
Parts Replacement
3 - 13
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602
3.3.7
Lower Base Unit
(1) Remove the upper cover (see 3.3.1).
(2) Remove the connecting cables 4 and 5 of the pulse and main motor from the connectors
2 and 3 of the Main Control board 1.
(3) Remove the screw 9 from the grounding cable and the metal shield. The screw is located
directly above CN1 and the 8-pin DIN connector for the second feeder/multi-purpose
feeder.
(4) Remove the connector 6 of the LED head from the Main Control board 1.
(5) Remove seven screws 7, then remove the lower base unit 8.
Note: Use care when lifting the lower base unit. Do not deform the ground clip 10 for the
second sheet feeder.
2
3
7
7
8
4 5
6
7
2
2
3
9
10
7