Centronics Parallel Interface
A - 1
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602
APPENDIX A: CENTRONICS PARALLEL INTERFACE
1)
Connector
• Printer side
:
36-pin receptacle
(single port) Type 57-40360-12-D56 (made by Daiichi Denshi) or
equivalent
• Cable side
:
36-pin plug
Type 57-30360 (made by Daiichi Denshi) or equivalent
Plug-552274-1 (AMP), 552073-1 (AMP) or equivalent
2)
Cable
• Cable length
:
6 ft (1.8 m) max.
•
A Shielded cable composed of twisted pair wires is required for FCC compliance.
•
IEEE-1284-compatible cable is required for use with DOS and Windows printer
conrtrol software.
Note: Cable is not supplied.