RE03 1406 EN
5 (48)
A remote control unit (option) can also be used for browsing and changing system
data and error notifications. The remote control unit can also be used as a remote
temperature sensor, providing the control system with room temperature data.
The system settings have been organised into menus, similar to folders on a computer.
In addition, there are various user levels in the system. The visibility of menus or
menu items depends on the user level. To access user levels other than
End user
or
Commissioning
, you need an access code.
1.5. Ground source heat pump operating principle
A ground source heat pump is a device that uses heat energy from the Sun that is
absorbed into Earth’s surface.
A
B
C
RE15 ver. 2
1. Evaporator
2. Compressor
3. Condenser
4. Expansion valve
A. Brine circuit
B. Refrigerant circuit
C. Heating circuit
There are three closed circuits running within, or through, the heat pump:
● brine circuit
● refrigerant circuit
● heating circuit.
The heat pump's operation is based on the vaporisation and condensation of the
refrigerant circulating within the heat pump.
The brine circuit is a circuit for collecting heat energy from the ground. When the brine
enters to the circuit at the evaporator, it is very cold. As it travels along the circuit, it
collects heat energy from the ground or water, which causes the brine temperature
to rise. The brine completes its circuit by returning to the evaporator and releasing
the heat energy into the refrigerant, which circulates between the evaporator and the
condenser.
Summary of Contents for RE 110
Page 2: ......
Page 45: ...RE03 1406 EN 43 48 WIPL02 ver 1 Figure1 Wilo IPL 50 115 0 75 2...
Page 46: ...44 48 RE03 1406 EN WIPL01 ver 1 Figure2 Wilo IPL 50 120 1 5 2 and Wilo IPL 50 130 2 2 2...
Page 47: ...RE03 1406 EN 45 48 WSP03 ver 1 Figure3 Wilo Stratos Para 25 1 7...
Page 51: ......
Page 52: ...www oilon com...