RE03 1406 EN
27 (48)
Cooling
mode button
If you have a separate air conditioning unit, you can connect the
heat pump to it and use the cooling mode button to change the heat
pump’s operation from heating to cooling.
By default, this button is not in use.
Reset button
Use the reset button to acknowledge and reset possible error
notifications that appear on screen.
Occupancy
button
Use the occupancy button of the remote controller to toggle
between the comfort setpoint and reduced setpoint. You can, for
example, set the heating mode to reduced setpoint when, there is
nobody home for a long period of time.
Note that the occupancy button is active only when the heating
mode is set to automatic (time program). The selection stays active
until the end of the currently running time program.
Display icons
Heating to comfort setpoint
Info level activated
Heating to reduced setpoint
Programming activated
Heating to frost protection
setpoint
Heating temporarily switched
off; ECO function active
Process running, please wait
Holiday program active
Heating circuit reference
A fault has occurred. Press the
information button for more
information.
The heat pump control system
has detected the same failure
frequently. This icon is also
visible when the emergency
use is active.
Change remote control unit
batteries, displayed only on
remote control unit (optional).
The heat pump will operate
normally even the batteries run
out of energy. The batteries life
is approximately 2 years.
Locating remote controller
Remote controller is an optional extra, these instructions applies only if remote
controller is part of the heat pump delivery.
The remote control unit is equipped with a built-in temperature sensor, which can be
used for heating circuit controlling.
As factory setting, this function is disabled. To activate the feature, see chapter
Using
remote controller as room temperature sensor
in installation manual.
Summary of Contents for RE 110
Page 2: ......
Page 45: ...RE03 1406 EN 43 48 WIPL02 ver 1 Figure1 Wilo IPL 50 115 0 75 2...
Page 46: ...44 48 RE03 1406 EN WIPL01 ver 1 Figure2 Wilo IPL 50 120 1 5 2 and Wilo IPL 50 130 2 2 2...
Page 47: ...RE03 1406 EN 45 48 WSP03 ver 1 Figure3 Wilo Stratos Para 25 1 7...
Page 51: ......
Page 52: ...www oilon com...