FIX mode (heating only)
4.5
IMPORTANT: Before starting, make sure the fi ltration pump is operating
correctly.
Step 1: Press
for 3 seconds to switch on your pump.
Step 2: Press
for 3 seconds to switch from one mode to the next until the FIX heating
mode is displayed.
Step 3: Select the desired temperature by pressing the arrow buttons and
(15 to 40 °C).
EXAMPLE:
If you have selected 28 °C, your screen will display the following:
Useful information:
IMPORTANT: After selecting the cooling or heating mode, the current
programme cannot be changed within an interval of 10 minutes.
When the water inlet temperature is lower or equal to the required temperature (target
temperature -1 °C), the heat pump will switch to heating mode. The compressor will stop
when the water inlet temperature is higher or equal to the desired temperature (target
tempe1 °C).
19
4.4 Fix Mode (heating only)
WARNING: Before starting, ensure that the filtration pump is operating correctly.
Step 1:
Long press
3s
to switch on your pump.
Step 2:
Long press
3s
to switch from one mode to another until the FIX Heating Mode is displayed.
Step 3:
Using buttons
and
select the required temperature (15-40°C).
EXAMPLE:
If you have selected 28°C, your screen will display:
Useful information:
WARNING: When the cooling mode switches to heating mode or vice-versa, the heat pump will
restart after 10 minutes.
When the incoming water temperature is less than or equal to the required temperature (setpoint tempera- ture -
1°C), the heat pump will switch to heating mode. The compressor will stop when the temperature of the incoming
water is greater than or equal to the required temperature (setpoint tempe 1°C).
Once the icon
SET
stops fl ashing, the
required temperature is saved and is
replaced by the current water tempe-
rature (25 °C in our example).
19
4.4 Fix Mode (heating only)
WARNING: Before starting, ensure that the filtration pump is operating correctly.
Step 1:
Long press
3s
to switch on your pump.
Step 2:
Long press
3s
to switch from one mode to another until the FIX Heating Mode is displayed.
Step 3:
Using buttons
and
select the required temperature (15-40°C).
EXAMPLE:
If you have selected 28°C, your screen will display:
Useful information:
WARNING: When the cooling mode switches to heating mode or vice-versa, the heat pump will
restart after 10 minutes.
When the incoming water temperature is less than or equal to the required temperature (setpoint tempera- ture -
1°C), the heat pump will switch to heating mode. The compressor will stop when the temperature of the incoming
water is greater than or equal to the required temperature (setpoint tempe 1°C).
“fl ashing”
target
temperature
Current water
temperature
Current ambient
air temperature