7.3.9 Replacing the cleaning corotron cartridge
A29246-X17-X-4-7680 / do701.fm
269
6.
Remove the corotron cartridge.
Remove any foreign matter from the U-
shaped guide bar.
Vacuum the U-shaped guide bar and
wipe off with a paper tissue.
7.
Insert a new corotron cartridge.
8.
Push the cleaning station back into the
system.
9.
Close the center doors.
10. Confirm prompts in the menu.
Press the <Exit> button.
11. Press <Ready>.
Proceed as follows: