User’s Guide Océ CS9160 printer
96
AP-40790 – Rev 2.0 -23/08/2011,
4.8.5.2 Settings that can be changed or confirmed while printing.
Notes
•
The Print start menu is displayed only when the printer is warming up.
•
When you change a setting during operation, be sure to select “Backup” to save the setting that
you changed.
•
If the printer returns to Normal without “Backup” being selected, the changed setting is not
saved
Setup Item
Setting
Description
Print Start
----
[ENTER] key: if the heater temperature does not
reach the set value during warming-up, printing
starts.
Temperature
Pre
Check the current Pre Heater temperature.
Platen
Check the current Platen Heater temperature
After
Check the current After Heater temperature
Pre Heater
OFF / 30°C to 50°C
Change the Pre Heater temperature
Platen Heater
OFF / 30°C to 50°C
Change the Platen Heater temperature
After Heater
OFF / 30°C to 50°C
Change the After Heater temperature
PF Adjust
-20 pulse to 0 to 20 pulse
Change the feed adjustment value
Backup
----
[ENTER] key: Save the changed setting.
----
[CANCEL] key: the printer returns to normal.
Summary of Contents for CS9160
Page 1: ...Oc CS9160 User s Guide Eco Solvent Low Solvent Ultra Bio Lactite...
Page 2: ...User s Guide Oc CS9160 printer 2 AP 40790 Rev 2 0 23 08 2011...
Page 6: ...User s Guide Oc CS9160 printer 6 AP 40790 Rev 2 0 23 08 2011...
Page 8: ...User s Guide Oc CS9160 printer 8 AP 40790 Rev 2 0 23 08 2011...
Page 17: ...User s Guide Oc CS9160 printer 17 AP 40790 Rev 2 0 23 08 2011 5 6 7 8 9...
Page 18: ...User s Guide Oc CS9160 printer 18 AP 40790 Rev 2 0 23 08 2011...
Page 114: ...User s Guide Oc CS9160 printer 114 AP 40790 Rev 2 0 23 08 2011...
Page 131: ...User s Guide Oc CS9160 printer 131 AP 40790 Rev 2 0 23 08 2011...