Installing the isCon® system
Routing on non-conductive building structures
When routed along a non-conductive building structure (e.g. stone, con-
crete or wood):
– Route electrically conductive connection rails (e.g. flat conductor, type
5052 V2A 30x3.5) in parallel to the isCon
®
conductor, which connect it
with the functional equipotential bonding of the building.
– Fasten the metallic isCon H VA conductor holder for the isCon
®
con-
ductor to it.
Fig 59:
≤ 500 mm
≤ 500 mm
isCon H VA
isCon
®
conductor in potentially explosive area with isCon H VA conductor holder
mounted on flat conductor
Routing along metallic pipes
– Connect the potential connection element to metal pipes routed in
parallel (equipotential bonding conductors) and connected to the
building's equipotential bonding at regular intervals.
Fig 60:
≤ 500 mm
isCon HS VA
Running the isCon
®
conductor on an earthed pipe in a potentially explosive area