Operating & Maintaining the Connex500/350 3-D Printer
7–54
DOC-13000 Rev. E
5. Disconnect
the
power
connection
to
the
UV
lamp.
Figure 7-86: Disconnecting the UV lamp
Note:
Do
not
disconnect the power connection to the cooling fans.
6. Loosen
the
screw
securing
the
UV
lamp
cover
(A)
,
and
pull
the
cover
up
(B)
,
then
out
(C)
.
Figure 7-87: Removing the UV lamp cover
7. Pull
the
lamp
reflector
out
of
the
block.
Figure 7-88: Removing the UV lamp reflector