DOC-13000 Rev. E
7–37
Connex500/350 User Guide
The
head
‐
purge
cycle
runs,
after
which
the
Weight
Test
is
printed.
Figure 7-52: Printing Weight Test
15. 32
samples
are
printed
on
the
build
tray,
four
for
each
of
the
heads.
This
can
take
up
to
55
minutes.
16. When
the
following
screen
appears,
open
the
printer
cover.
Enter
the
data
that
describes
the
condition
of
each
head,
after
inspecting
each
of
the
printed
samples.
Figure 7-53: Weight Test Data Entry screen
a. Enter
the
number
of
faulty
(“missing”)
nozzles.
Faulty
nozzles
are
seen
in
Weight
Test
samples
as
a
missing
row
of
printed
material.
Compare
the
height
of
the
missing
row
with
the
lines
printed
on
the
“missing
nozzles”
ruler.
Enter
the
number
next
to
the
line
that
most
closely
matches
the
height
of
the
missing
row.
The layout of the data entry screen matches the printed samples on the
build tray. Enter the data for the sample indicated by
in the screen.