DOC-13000 Rev. E
7–53
Connex500/350 User Guide
adjust
their
effective
power
with
the
UV
Calibration
Wizard
(see
“Testing
and
Calibrating
the
UV
Lamps”
on
page 49.
If
you
need
to
replace
a
UV
lamp,
follow
these
instructions:
1. Make
sure
the
Connex
printer
is
in
offline
mode.
Figure 7-83: Offline mode indicator (red)
The
online/offline
button
at
the
bottom
of
the
printer
interface
should
be
red.
If
not,
click
it
to
switch
the
printer
to
offline
mode.
2. Start
the
UV
Lamp
Replacement
wizard.
From
the
Options
menu
of
the
printer
interface
(see
figure 7
‐
26
on
page 23),
select
Wizards > UV Lamp Replacement
.
3. Make
sure
that
the
build
tray
is
empty,
and
confirm
this
in
the
wizard
screen.
Then,
close
the
printer
cover
and
click
Next
.
Figure 7-84: “Empty tray” confirmation screen
The
axes
move
to
the
“home”
position.
4. Select
the
UV
lamp(s)
to
be
replaced
and
click
Next
.
Figure 7-85: UV lamp selection screen
WARNING:
Before continuing, make sure that the safety interlock in the
printer cover is not defeated, and that the lamp is not hot.