OPERATOR & MAINTENANCE MANUAL
32
6. Maintenance
Before performing any check or maintenance, stop the engine and remove the start key
For detailed maintenance procedures on the engine, refer to engine operator's manual.
6.1 Periodic Maintenance Schedule
Service items
Daily
Or
After
8 hrs
Weekly
Or
After
50 hrs
Monthly
Or
After
100 hrs
6
Months
Or
After
250 hrs
Yearly
Or
After
500 hrs
2
Years
Or
After
1000
hrs
Check various meters and alarm
lamps
●
Check engine oil , fuel and
coolant level
●
Check for leaks (oil, fuel and
coolant)
●
Check air cleaner dust cap
●
Check generator visually
●
Check battery charging system
●
Check drive belt tension
●
●
Drain water/sediment from fuel
filter
●
Drain water/sediment from fuel
tank
●
Change engine oil and replace
oil filter
●
Change fuel filter element
●
Clean or change air filter
element
●
Change
●
Change
Check cooling system
●
Clean unit inside and outside
●
Change coolant
●
Pressure test cooling system
●
Clean inside fuel tank
●
6.2 New Machines
Run the generator at least 60–100% of continuous load for the first 100 hours.
Change engine oil and replace oil filter after the first 50 hours.