background image

 

 
 

2. IMPORTANT NOTES 

a.  

This appliance must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer. 

b. 

The connection of this appliance and ventilation requirements (if any) are to be according to National & Local Codes.  

c.  

This appliance does not normally require any purpose provided additional ventilation, however if it as been found necessary to 
add a vent periodically check that it is free from obstruction. 

d.

   Consult all Instructions before Installation and Use. 

e.

   Do not throw rubbish on, or attempt to burn any materials on this appliance. Any Debris or Foreign Matter must be removed from 

the fire.  

f.

   Under No Circumstances must this fire be used if the Glass Panel is broken damaged or cracked or if the Door Seal is damaged.  

g.

  The inner glass door, outer trim and outer glass door (if applicable) of this fire will become very hot during use, cloths or  

      combustible items must not be placed close to or on the fire.  

Very Important: We recommend that a Fireguard conforming to BS8423 should be used for protection of Young Children 
                            the Elderly, Infirm and Pets. 
h.

   The appliance should be Serviced Annually in accordance with the Gas Safety & Uses Regulations. 

i.

   Where the flue has been used for Solid Fuel it must be swept before Installation.  

j.

   If at any time you smell gas or fumes turn the fire off and contact your Installer.    

k.

   These Instructions must be left with the User for future reference. 

l.  

During its first period of use any protective coatings and oils will burn out of the appliance and it is wise to ventilate the room for 
the first few hours of use. 

m. 

This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the fire if the 

 

oxygen level in the room is depleted, due to lack of primary air, or obstructed flue (blocked chimney) that would lead to  

 

incomplete combustion of the gas. It must not be tampered with and only replaced with a genuine Nu-Flame ODS. 

n.

   In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem, call in a properly 

qualified specialist engineer. 

o.

  There are no user replaceable parts in the appliance apart from the batteries. 

p.

   The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no

 

 build up of soot. If there is, the appliance must be serviced.  

q.  

Simulated logs and simulated bark chips, manufactured from refractory fibre, are supplied with this appliance. Do not use real 
logs or real bark chips as this is dangerous. If the simulated logs or simulated bark chips need renewing please obtain suitable 
replacements from a Nu-Flame Stockist.  

r.  

The fire must be installed in accordance with the rules in force and these Instructions it must be installed into a builders opening 
as detailed in these Instructions. 

s.   

No

 

combustible materials e.g. curtains must be closer than 500mm to the fire. 

t. 

For Fire Surround Applications a 150mm (6”) combustible shelf can be fitted above the fire provided it is 350mm above the  

 

Fireplace Opening. 

u.  

The Fire can be installed into a suitably designed fire surround with a 150

º

C Rating. 

v. 

Take

 

care with some Micro Marble Materials claiming a 150

º

C Rating as they may give off odours, blister or discolour.  

w.

  Ensure the Door Release Screwdriver is left with the customer and if possible show them how to open the door for cleaning and 

how to secure the door after cleaning. When a Glass Outer Door is provided show the Customer how to Open The Door by  

      pulling open at the lower left side. Stress that this should only be done when the fire is cool.    

x.

   Explain to the customer that over time some wall staining will occur and this is due primarily to particles of dust present in the hot 

convection air circulating up and over the fire and sticking to the wall. 

y.

  If a Wall Mounted Television is mounted above the fire you must take account of the Television Manufacturers Instructions.  

     The Installation requirements provided with these Instructions must be adhered to for such installations and are provided to    

ensure an acceptable ambient temperature is provided above the fire.  

y.

  In adverse weather conditions where high winds are experienced it is possible that products of combustion/smoke could be 

blown down into the room, a condition known as Down Draught. You 

Must 

contact your Installer immediately if this is  

      experienced and turn the fire off and do not use it until the problem is corrected. 

! WARNINGS & IMPORTANT NOTES !  THE THERMOSTATIC THERMOTRONIC CONTROL SYSTEM PROVIDES THE MEANS 

 FOR UNATTENDED OPERATION OF THE FIRE IF THE PROGRAMS OR THERMOSTATE SETTINGS 

 ARE USED - THIS COULD POSE A DANGER IF COMBUSTIBLE MATERIALS ARE TOO CLOSE TO 

 THE FIRE OR IF YOUNG CHILDREN, THE ELDERLY, INFIRM OR PETS ARE LEFT UNATTENENDED.  

THE INNER GLASS DOOR AND/OR OUTER GLASS DOOR ON THESE FIRES WILL BECOME VERY 

 HOT DURING USE THEREFORE IT IS VITAL THAT GUARDING  IS PROVIDED - SEE ITEM G. ABOVE. 

THE SYNERGY RANGE HAS A UNIQUE BURNER SYSTEM WHERE THE FLAME SIZES AND COLOURS WILL CHANGE    

& THE FIRE WILL ALSO MAKE POPPING & BURBLING NOISES LIKE A REAL FIRE 

 

THE SYNERGY ELLESSE  

USER INSTRUCTIONS  

Health & Safety Advice  

Refractory Ceramic Fibre (RCF)  

Advice when working with Fuel Bed Components including Installing, Servicing and Disposal.  

 

The Fuel Effect parts and possible Linings of this fire are made from Refractory Ceramic Fibre (R.C.F.) a Class 2 Carcinogen which is 
 a material designed for this Application. Excessive exposure to these types of materials may cause temporary irritation to eyes, skin  
and respiratory tract. Therefore take care when handling these articles to ensure dust is kept to a minimum. 
It is not necessary to wear protective clothing when handling these articles but we do recommend you follow the normal hygiene rules of 
not smoking, eating or drinking in the work area, and always wash your hands before eating or drinking.  
To minimise the release of RCF fibres during installation and servicing a HEPA filtered vacuum is recommended to remove any dust  
accumulated in and around the fire both before and after working on it.  
When Servicing and if replacing these parts we do not recommend they are broken up but are sealed within a heavy duty polythene 
Bag and labelled as “RCF waste”. This is not classified as “hazardous waste” and may be disposed of at a local licensed landfill site.  

Summary of Contents for SYNERGY ELLESSE

Page 1: ...FIRE IS HEAVY AND ASSISTANCE SHOULD BE SOUGHT WHEN LIFTING ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Business Centre Minden Ro...

Page 2: ...12 Hole in the Wall Installations for Steel Glass Trim Styles 12 With Appropriate Sealing Frame 13 Hole in the Wall Installations for Echo Trim Style 14 14 Hole in the Wall Installations with Marble...

Page 3: ...rone to being chipped or scratching 1 2 Removal of Components a Fires Ordered with Steel or Glass Trims i The Outer Door will have to be removed and stored carefully to allow access for removal of the...

Page 4: ...he Fire can be installed into a suitably designed fire surround with a 150 C Rating v Take care with some Micro Marble Materials claiming a 150 C Rating as they may give off odours blister or discolou...

Page 5: ...nked by arrow Please note that you can have the flame height anywhere between maximum and preset low For fine adjustment simply tap the large and small flame buttons d Switching Off Press the red off...

Page 6: ...esent room temperature the fire will go straight to the Standby Setting until the temperature drops below the Set Temperature at which point the main burner will relight Note The Room Temperature is s...

Page 7: ...ELDERLY OR INFIRM OR PETS ARE LEFT IN ATTENDANCE 3 5 RESETTING THE MERTIK MAXITROL LOGIC CIRCUITS IF THE HANDSET DOES NOT WORK APPLIES TO BOTH CONTROL SYSTEMS Must only be done when the fire is Cool B...

Page 8: ...of the door Follow instructions in section b above e The logs must not be cleaned or moved f The outer surfaces of the fire can be cleaned with a damp lint free cloth do not use abrasive cleaners IMPO...

Page 9: ...FORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS...

Page 10: ...Height mm Synergy Ellesse Echo Trim with Metal Door 1140mm 540mm Synergy Ellesse Echo Trim with Glass Door 1140mm 540mm Synergy Ellesse Steel Trim No Sealing Frame 1135mm 560mm Synergy Ellesse Steel...

Page 11: ...PPLIANCE SEEK EXPERT ADVICE 10 VENTILATION a No additional purpose provided ventilation is normally required for the fire when installed in the UK however this must be confirmed by the Spillage Test s...

Page 12: ...rials d No combustible materials must present in the builders opening e The base of the builders opening must be flat level and square to the wall f The builders opening should have provision for a ga...

Page 13: ...rs opening d If the silicone sealing strip is not compressed and there are gaps they must be filled with a suitable sealant fireclay or high temperature silicone Wall staining may occur if the seals a...

Page 14: ...placed too close e No combustible material e g curtains must be closer than 500mm to the builders opening The wall between the sealing frame and any shelf would become hot Therefore we do not recomme...

Page 15: ...with a suitable sealant fireclay or high temperature silicone j Refit the burner mounting plate assembly by first putting the Receiver through the opening then tilt the assembly and slide it into the...

Page 16: ...ng structural check may be required c The builders opening must be constructed from Non combustible materials d No combustible materials must present in the builders opening e The base of the builders...

Page 17: ...ay in position to make a seal against the top edge of the slip at the base of the builders opening and the front face of the slips where they locate against the rear of the Fire outer frame While slid...

Page 18: ...any rendering building work is allowed to thoroughly dry out before Installation IMPORTANT Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the...

Page 19: ...slightly and slide it home ensuring that the sealing strips on the underside of the front riser channel and the rear of the Fire outer frame stay in position to make a seal against the base of the fi...

Page 20: ...y Breast will occur e The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer s requirements and spaces the Television at least 35mm...

Page 21: ...osition for a Wall Mounted Television Must meet the Installation Requirements of these Instructions e The Nu Flame Television Glass Heat Shield is only suitable for the Nu Flame Synergy Range of Gas F...

Page 22: ...the Fire s Installation Instructions and the Fire Surround meets the Minimum Dimensions as detailed in the Diagrams Below b You Must take account of the Television Manufacturer s Installation requirem...

Page 23: ...fuel tray g Place the large rear log No 1 to the rear of the fire on the fuel tray ensuring that the cut out in the log sits behind the pilot shield and that it is central about the burner h Place lo...

Page 24: ...n the log support at the front k Place log No 5 next to log No 6 locating it on the peg and the cut out in the rear log l Place the last log No 4 so that it locates on the central peg and rests in the...

Page 25: ...Emberglow material is a consumable material and as a limited life You can buy replacements through your local Nu Flame Ltd Stockist or Installer q For Synergy Perspective Glass Wall Mounted Installati...

Page 26: ...m or adjacent rooms running at high The fire should continue to clear its combustion products Also operate any other flued appliance in the same or neighbouring rooms and ensure they continue to funct...

Page 27: ...ii Now secure the upper Hinge Pin with the fixing screw provided as shown the door should then be closed and held shut by the magnet catches Very Important The Hinge Pin Screw Must be fitted to ensur...

Page 28: ...SES WHEN LIT 20 SERVICING 20 1 GENERAL Note Servicing must be carried out by a registered installer a The fire does not have to be removed for Servicing b Check the operation and ignition of the fire...

Page 29: ...Burner Control Assembly to Nu Flame for rectification as this could be the least cost option 21 3 PILOT GOES OUT AFTER FIRST LIGHTING a Check there is no vermiculite blocking the flame to the thermoco...

Page 30: ...ork d Change the Handset and or Receiver and or Burner Control System Important In instances where it is indicating that either of the main control systems need changing you should investigate returni...

Page 31: ...5 4 The fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame L...

Page 32: ...fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited...

Page 33: ...33 23 DIAGRAM OF INFRARED CONTROL SYSTEM...

Page 34: ...elivery to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during th...

Reviews: