3.4 - BATTERY REPLACEMENT 

Applies to both Control Systems - (Must only be done when the fire is Cool) 
a.   

A feature of the Thermostatic Thermatronic Handset is it as a Battery Charge Indicator shown in the screen on the 

Handset which will determine when both the Handset and Receiver Batteries need changing, however also see 

‘b’

.     

b.

  For Both Control systems, Battery replacement is recommended at the beginning of each heating season, or when an acoustic 

error message sounds during ignition. 

c.

  Error Message – Long signals (0.8 second tone – 0.2 second break) during ignition –  probable cause - batteries in electronic 

receiver box are nearly discharged. 

d.

  Error Message – 5 second continuous tone – probable cause – cable disconnected or  on/off switch on  valve is in off position. 

e.

  Batteries - Electronic Receiver Box - 4 x AA good quality alkaline - Handset - 1 x PP3 good quality alkaline. 

f. 

To change the Handset battery slide open the plastic panel on the back of the Handset. 

g.

   To change the Receiver Batteries open the outer door by pulling pull at the left side to release it from the magnetic catches. 

       Locate the electronic receiver box, underneath the fire on the left hand side.  Slide open the plastic cover to gain access to the 

battery compartment. You can detach the Receiver by pulling it off its Velcro Pad to make access easier but remember to put it 
back in the same position. 

                                     Note: Only Change The Batteries When The Fire Is Cold   

 

! WARNING!  THE THERMOSTATIC THERMOTRONIC CONTROL SYSTEM PROVIDES THE 
MEANS FOR UNATTENDED OPERATION OF THE FIRE IF THE PROGRAMS OR THERMOSTATE  
SETTINGS ARE USED - THIS COULD POSE A DANGER IF COMBUSTIBLE MATERIALS ARE TOO 
CLOSE TO THE FIRE OR IF YOUNG CHILDREN, THE ELDERLY OR INFIRM OR PETS ARE LEFT IN 
 ATTENDANCE.  

 

3.5 - RESETTING THE MERTIK MAXITROL LOGIC CIRCUITS - IF THE HANDSET DOES NOT WORK 

                                                  APPLIES TO BOTH CONTROL SYSTEMS  
 

Must only be done when the fire is Cool 

 

Basic Reset - 

It sometimes happens that (such as when the handset buttons are pressed out of sequence) the fire stops 

working because the logic circuits get confused and need to be reset.  

 

To do this, simply remove the 4 x AA batteries from the Receiver Box  (see section 2.4f above), wait for 1 minute and then refit the 
batteries. Wait for another minute and then point the handset at the fire and press the red/off  button. Wait for another minute and 
then start the fire as normal. If the fire does not start repeat the resetting procedure. If the fire still does not work a Full Reset can be 
tried. 
 

Full Reset 

- If you obtain a new handset the control system will need to learn the handset’s unique code via a Full Reset. Also, if the 

fire is not working and the Basic Reset  has not worked a Full Reset can be carried out: 

 

 

Open the outer door by pulling at the left side to release it from the magnetic catches and open the outer door, locate the electronic 
Receiver Box.   
Locate the Reset Hole on the side of the Receiver and using a pen press and hold in the Reset button until you hear two beeps. 
The first beep is short and the second beep is long. After the second beep release the Reset Button. 
Now on the Handset, within the next 20 seconds press and hold the Small Flame Button until you hear two additional short beeps  
confirming the code is set in the Receiver.  
If you hear one long beep the Code as not been set so repeat the procedure. 

 

If after carrying out the above procedure the situation is not corrected it will be necessary to contact your Installer.  
 

Note: For the Installation/Service Engineer 

- Resetting of the Handset & Control System is also covered in Section 21.1 page 29. 

 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SYNERGY ELLESSE

Page 1: ...FIRE IS HEAVY AND ASSISTANCE SHOULD BE SOUGHT WHEN LIFTING ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Business Centre Minden Ro...

Page 2: ...12 Hole in the Wall Installations for Steel Glass Trim Styles 12 With Appropriate Sealing Frame 13 Hole in the Wall Installations for Echo Trim Style 14 14 Hole in the Wall Installations with Marble...

Page 3: ...rone to being chipped or scratching 1 2 Removal of Components a Fires Ordered with Steel or Glass Trims i The Outer Door will have to be removed and stored carefully to allow access for removal of the...

Page 4: ...he Fire can be installed into a suitably designed fire surround with a 150 C Rating v Take care with some Micro Marble Materials claiming a 150 C Rating as they may give off odours blister or discolou...

Page 5: ...nked by arrow Please note that you can have the flame height anywhere between maximum and preset low For fine adjustment simply tap the large and small flame buttons d Switching Off Press the red off...

Page 6: ...esent room temperature the fire will go straight to the Standby Setting until the temperature drops below the Set Temperature at which point the main burner will relight Note The Room Temperature is s...

Page 7: ...ELDERLY OR INFIRM OR PETS ARE LEFT IN ATTENDANCE 3 5 RESETTING THE MERTIK MAXITROL LOGIC CIRCUITS IF THE HANDSET DOES NOT WORK APPLIES TO BOTH CONTROL SYSTEMS Must only be done when the fire is Cool B...

Page 8: ...of the door Follow instructions in section b above e The logs must not be cleaned or moved f The outer surfaces of the fire can be cleaned with a damp lint free cloth do not use abrasive cleaners IMPO...

Page 9: ...FORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS...

Page 10: ...Height mm Synergy Ellesse Echo Trim with Metal Door 1140mm 540mm Synergy Ellesse Echo Trim with Glass Door 1140mm 540mm Synergy Ellesse Steel Trim No Sealing Frame 1135mm 560mm Synergy Ellesse Steel...

Page 11: ...PPLIANCE SEEK EXPERT ADVICE 10 VENTILATION a No additional purpose provided ventilation is normally required for the fire when installed in the UK however this must be confirmed by the Spillage Test s...

Page 12: ...rials d No combustible materials must present in the builders opening e The base of the builders opening must be flat level and square to the wall f The builders opening should have provision for a ga...

Page 13: ...rs opening d If the silicone sealing strip is not compressed and there are gaps they must be filled with a suitable sealant fireclay or high temperature silicone Wall staining may occur if the seals a...

Page 14: ...placed too close e No combustible material e g curtains must be closer than 500mm to the builders opening The wall between the sealing frame and any shelf would become hot Therefore we do not recomme...

Page 15: ...with a suitable sealant fireclay or high temperature silicone j Refit the burner mounting plate assembly by first putting the Receiver through the opening then tilt the assembly and slide it into the...

Page 16: ...ng structural check may be required c The builders opening must be constructed from Non combustible materials d No combustible materials must present in the builders opening e The base of the builders...

Page 17: ...ay in position to make a seal against the top edge of the slip at the base of the builders opening and the front face of the slips where they locate against the rear of the Fire outer frame While slid...

Page 18: ...any rendering building work is allowed to thoroughly dry out before Installation IMPORTANT Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the...

Page 19: ...slightly and slide it home ensuring that the sealing strips on the underside of the front riser channel and the rear of the Fire outer frame stay in position to make a seal against the base of the fi...

Page 20: ...y Breast will occur e The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer s requirements and spaces the Television at least 35mm...

Page 21: ...osition for a Wall Mounted Television Must meet the Installation Requirements of these Instructions e The Nu Flame Television Glass Heat Shield is only suitable for the Nu Flame Synergy Range of Gas F...

Page 22: ...the Fire s Installation Instructions and the Fire Surround meets the Minimum Dimensions as detailed in the Diagrams Below b You Must take account of the Television Manufacturer s Installation requirem...

Page 23: ...fuel tray g Place the large rear log No 1 to the rear of the fire on the fuel tray ensuring that the cut out in the log sits behind the pilot shield and that it is central about the burner h Place lo...

Page 24: ...n the log support at the front k Place log No 5 next to log No 6 locating it on the peg and the cut out in the rear log l Place the last log No 4 so that it locates on the central peg and rests in the...

Page 25: ...Emberglow material is a consumable material and as a limited life You can buy replacements through your local Nu Flame Ltd Stockist or Installer q For Synergy Perspective Glass Wall Mounted Installati...

Page 26: ...m or adjacent rooms running at high The fire should continue to clear its combustion products Also operate any other flued appliance in the same or neighbouring rooms and ensure they continue to funct...

Page 27: ...ii Now secure the upper Hinge Pin with the fixing screw provided as shown the door should then be closed and held shut by the magnet catches Very Important The Hinge Pin Screw Must be fitted to ensur...

Page 28: ...SES WHEN LIT 20 SERVICING 20 1 GENERAL Note Servicing must be carried out by a registered installer a The fire does not have to be removed for Servicing b Check the operation and ignition of the fire...

Page 29: ...Burner Control Assembly to Nu Flame for rectification as this could be the least cost option 21 3 PILOT GOES OUT AFTER FIRST LIGHTING a Check there is no vermiculite blocking the flame to the thermoco...

Page 30: ...ork d Change the Handset and or Receiver and or Burner Control System Important In instances where it is indicating that either of the main control systems need changing you should investigate returni...

Page 31: ...5 4 The fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame L...

Page 32: ...fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited...

Page 33: ...33 23 DIAGRAM OF INFRARED CONTROL SYSTEM...

Page 34: ...elivery to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during th...

Reviews: