Nu-Flame SYNERGY ELLESSE Use, Installation & Servicing Instructions Download Page 20

20 

 

               
                      

IMPORTANT: THE STEEL TRIM OPTION WHEN WALL MOUNTED IS NOT   
                                         SUITABLE FOR A WALL MOUNTED TELEVSION.  
 
These Instructions detail the Installation Requirements for Wall Mounted Televisions when Installed 
above the Fire and should be considered with all other Installation Requirements of the Fire. 
 
IMPORTANT:   Due to the High Heat Output of the Fire The Installation Requirements of these  
                            Instructions MUST be Adhered To For Wall Mounted Televisions. 

 

 

IMPORTANT:   The Fire and Trim Style will affect the height and position of the Television therefore it 

is important to check what height position options are possible and acceptable. 

 
16.1 - GENERAL 

Before continuing with the Television Installation it is important to determine if there is the  likelihood of the Chimney Breast 
becoming hot when the Fire is in operation. Some of these checks will only provide assistance if a fire has been previously 
installed. The following checks will assist but are not conclusive.  
a.  

Typically Class 1 flues with Dry Lined Walls will normally have acceptable Wall Temperatures provided the air gap is fully sealed 

      around the builders opening.

 

b.  

If a gas fire was installed and the chimney breast shows any signs of over heating e.g. discoloured wall paper, then do not  

      consider  Installing a Wall Mounted Television as the Temperatures are likely to be too high. 

c.  

If a gas fire was installed and the Chimney Breast is finished in Wall Paper and shows no signs of temperature damage  

      then the Wall Temperatures are likely to be acceptable so the Installation can proceed.   

d.  

A Wall Mounted Television Must Not be sunk into the wall as it will not be in an acceptable ventilated position and this is only  

     acceptable if additional fan cooling ventilation is provided. It is also likely that higher temperatures from the flue within the  
      Chimney Breast will occur.  

e.  

The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer’s 

      requirements and spaces the Television at least 35mm away from the Chimney Breast.  

f.  

After reading the Installation Requirements you should compare this with the preferred height position of the Television. 

 
16.2 - TELEVISION GLASS HEAT SHIELD INSTALLATION REQUIREMENTS 

Reference Must Also Be Made to the Installations Requirements for Each Type of Trim as Detailed on the Following Pages 

      

Where the Installation requires the fitting of the Television Glass Heat Shield the following instructions apply.  
Important 

-  Before proceeding with the Installation of the Television Heat Shield confirm the preferred Height Position of the 

                     Television with the Customer.  
 

a

.   It is recommended that, for aesthetic reasons, due consideration is given prior to Installation for the provision of main s 

     electric, aerial, sound and any other Connections that may wish to be hidden behind the Television.  
     A Qualified Electrician/Specialist should be consulted. 

b.  

Reference should be made to the diagram below for the position of the hole fixings which should be above the minimum  

     height as shown in the different Installation Requirements on the following pages.  

c

.  Determine the height position to the base of the Television Heat Shield from the relevant Installation Diagrams on the nex t 

     page and draw a line for reference ensuring it is level. 

d

.  Mark out the holes as shown in the diagram but before drilling recheck your dimensions ensuring the height of the  

     Television is correct and the distances will be as required. 

e

.   Before drilling the holes check for the positions of any wires within the wall  

f.    

Ensure the wall is sound and the fixings will be secure for the Television Heat Shield before proceeding with fitting.  

 
 

 

 

16.  INSTALLATION INSTRUCTIONS FOR WALL MOUNTED TELEVISIONS 
                                      ADITIONAL REQUIREMENTS  

 

Television Heat Shield Fixing Hole Centres 
 Ensure the Base is at the Correct Distance 
 

Summary of Contents for SYNERGY ELLESSE

Page 1: ...FIRE IS HEAVY AND ASSISTANCE SHOULD BE SOUGHT WHEN LIFTING ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Business Centre Minden Ro...

Page 2: ...12 Hole in the Wall Installations for Steel Glass Trim Styles 12 With Appropriate Sealing Frame 13 Hole in the Wall Installations for Echo Trim Style 14 14 Hole in the Wall Installations with Marble...

Page 3: ...rone to being chipped or scratching 1 2 Removal of Components a Fires Ordered with Steel or Glass Trims i The Outer Door will have to be removed and stored carefully to allow access for removal of the...

Page 4: ...he Fire can be installed into a suitably designed fire surround with a 150 C Rating v Take care with some Micro Marble Materials claiming a 150 C Rating as they may give off odours blister or discolou...

Page 5: ...nked by arrow Please note that you can have the flame height anywhere between maximum and preset low For fine adjustment simply tap the large and small flame buttons d Switching Off Press the red off...

Page 6: ...esent room temperature the fire will go straight to the Standby Setting until the temperature drops below the Set Temperature at which point the main burner will relight Note The Room Temperature is s...

Page 7: ...ELDERLY OR INFIRM OR PETS ARE LEFT IN ATTENDANCE 3 5 RESETTING THE MERTIK MAXITROL LOGIC CIRCUITS IF THE HANDSET DOES NOT WORK APPLIES TO BOTH CONTROL SYSTEMS Must only be done when the fire is Cool B...

Page 8: ...of the door Follow instructions in section b above e The logs must not be cleaned or moved f The outer surfaces of the fire can be cleaned with a damp lint free cloth do not use abrasive cleaners IMPO...

Page 9: ...FORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS...

Page 10: ...Height mm Synergy Ellesse Echo Trim with Metal Door 1140mm 540mm Synergy Ellesse Echo Trim with Glass Door 1140mm 540mm Synergy Ellesse Steel Trim No Sealing Frame 1135mm 560mm Synergy Ellesse Steel...

Page 11: ...PPLIANCE SEEK EXPERT ADVICE 10 VENTILATION a No additional purpose provided ventilation is normally required for the fire when installed in the UK however this must be confirmed by the Spillage Test s...

Page 12: ...rials d No combustible materials must present in the builders opening e The base of the builders opening must be flat level and square to the wall f The builders opening should have provision for a ga...

Page 13: ...rs opening d If the silicone sealing strip is not compressed and there are gaps they must be filled with a suitable sealant fireclay or high temperature silicone Wall staining may occur if the seals a...

Page 14: ...placed too close e No combustible material e g curtains must be closer than 500mm to the builders opening The wall between the sealing frame and any shelf would become hot Therefore we do not recomme...

Page 15: ...with a suitable sealant fireclay or high temperature silicone j Refit the burner mounting plate assembly by first putting the Receiver through the opening then tilt the assembly and slide it into the...

Page 16: ...ng structural check may be required c The builders opening must be constructed from Non combustible materials d No combustible materials must present in the builders opening e The base of the builders...

Page 17: ...ay in position to make a seal against the top edge of the slip at the base of the builders opening and the front face of the slips where they locate against the rear of the Fire outer frame While slid...

Page 18: ...any rendering building work is allowed to thoroughly dry out before Installation IMPORTANT Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the...

Page 19: ...slightly and slide it home ensuring that the sealing strips on the underside of the front riser channel and the rear of the Fire outer frame stay in position to make a seal against the base of the fi...

Page 20: ...y Breast will occur e The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer s requirements and spaces the Television at least 35mm...

Page 21: ...osition for a Wall Mounted Television Must meet the Installation Requirements of these Instructions e The Nu Flame Television Glass Heat Shield is only suitable for the Nu Flame Synergy Range of Gas F...

Page 22: ...the Fire s Installation Instructions and the Fire Surround meets the Minimum Dimensions as detailed in the Diagrams Below b You Must take account of the Television Manufacturer s Installation requirem...

Page 23: ...fuel tray g Place the large rear log No 1 to the rear of the fire on the fuel tray ensuring that the cut out in the log sits behind the pilot shield and that it is central about the burner h Place lo...

Page 24: ...n the log support at the front k Place log No 5 next to log No 6 locating it on the peg and the cut out in the rear log l Place the last log No 4 so that it locates on the central peg and rests in the...

Page 25: ...Emberglow material is a consumable material and as a limited life You can buy replacements through your local Nu Flame Ltd Stockist or Installer q For Synergy Perspective Glass Wall Mounted Installati...

Page 26: ...m or adjacent rooms running at high The fire should continue to clear its combustion products Also operate any other flued appliance in the same or neighbouring rooms and ensure they continue to funct...

Page 27: ...ii Now secure the upper Hinge Pin with the fixing screw provided as shown the door should then be closed and held shut by the magnet catches Very Important The Hinge Pin Screw Must be fitted to ensur...

Page 28: ...SES WHEN LIT 20 SERVICING 20 1 GENERAL Note Servicing must be carried out by a registered installer a The fire does not have to be removed for Servicing b Check the operation and ignition of the fire...

Page 29: ...Burner Control Assembly to Nu Flame for rectification as this could be the least cost option 21 3 PILOT GOES OUT AFTER FIRST LIGHTING a Check there is no vermiculite blocking the flame to the thermoco...

Page 30: ...ork d Change the Handset and or Receiver and or Burner Control System Important In instances where it is indicating that either of the main control systems need changing you should investigate returni...

Page 31: ...5 4 The fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame L...

Page 32: ...fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited...

Page 33: ...33 23 DIAGRAM OF INFRARED CONTROL SYSTEM...

Page 34: ...elivery to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during th...

Reviews: