background image

4221 - 0111-01
04/14  Rev. 00

IMWK10.5KC-

KCT 

Printed in South Korea

P O R TA B L E

K E R O S E N E - H E AT E R

“OWNER’S  MANUAL”

DuraHeat

®

Before  the  first  use  of  this  heater,  please  read  this  OWNER'S  MANUAL  very

 

carefully. This OWNER'S MANUAL has been designed to instruct you as to the

 

proper manner in which to assemble the heater, maintain the heater, store the

 

heater, and most importantly, how to operate the heater in a safe and efficient

 

manner, please keep this manual for future reference.

MODEL: DH 1051

World Marketing of America, Inc.

RT.22 West, P.O. Box 192

Mill Creek, PA 17060

Telephone : 814-643-1775 (9AM - 4PM EST)

www.yourheater.com

Summary of Contents for DH1051

Page 1: ...NER S MANUAL has been designed to instruct you as to the proper manner in which to assemble the heater maintain the heater store the heater and most importantly how to operate the heater in a safe and efficient manner please keep this manual for future reference MODEL DH 1051 World Marketing of America Inc RT 22 West P O Box 192 Mill Creek PA 17060 Telephone 814 643 1775 9AM 4PM EST www yourheater...

Page 2: ...h the door closed NEVER use heater to heat or boil water or use as a cooking appliance WARNING FAILURE TO INSTALL MAINTAIN AND OR OPERATE THIS KEROSENE HEATER ACCORDING TO MANUFACTURER S INSTRUCTIONS MAY RESULT IN CONDITIONS WHICH CAN PRODUCE BODILY INJURY AND OR PROPERTY DAMAGE NOTE The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and ...

Page 3: ...s separately Fig A and never operate heater while it is unattended Fig F The usage of Gasoline can lead to flare up in a kerosene heater leading to a destructive fire 1 NEVER operate the heater without a working fire extinguisher and smoke detector nearby Fig B 2 NEVER use any fuel other than water clear 1 K kerosene ALWAYS check kerosene for clarity at the point of purchase NEVER use fuels such a...

Page 4: ... room for any period of time Fig F 10 NEVER leave the heater operating when you go to bed Fig G 11 ALWAYS allow heater to cool for at least 15 minutes before you move it or remove its fuel tank for refueling or servicing 12 ALWAYS confirm extinguishment of the flame by raising the burner knob and checking visually 10 to 15 seconds after turning off the heater 13 NEVER place any objects on the top ...

Page 5: ...ene remove carbon deposits on the wick periodically in accordance with the operating instructions in the Owner s Manual and adjust wick setting periodically in accordance with the operating instructions in the Owner s Manual Fig N 1 NEVER operate the heater while it is unattended 2 NEVER operate the heater without a working smoke detector and fire extinguisher nearby 3 NEVER use poor quality keros...

Page 6: ...NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 6 ...

Page 7: ...IGNITION SYSTEM ADJUSTING THE WICK WICK MAINTENANCE ITEM ITEM PAGE 2 7 7 8 9 10 11 11 12 13 13 14 14 17 17 18 19 20 20 20 CARBON REMOVAL DRY BURNING WICK ASSEMBLY WICK REPLACEMENT EXTINGUISHING THE HEATER AUTOMATIC SAFETY SHUT OFF DEVICE LONG TERM STORAGE OF YOUR HEATER TROUBLE SHOOTING GUIDE PARTS LIST EXPLODED PARTS DRAWING SPECIFICATIONS PAGE CONTENTS OF OWNER S MANUAL INTRODUCTION Please read ...

Page 8: ...ss from Middle plate and remove Lower pad on Middle plate Fig 3 FIG 4 related Place the Glass on the Middle plate Place Top plate on the Glass Assemble Grill Glass fix on the Middle plate Align and insert 4 bended rods to Clipped Guides on Middle plate Fig 4 Align the 2 holes on Top Grill with the 2 mounting holes on the Guard Grill as shown in Fg 5 Secure each holes with a screw NEVER LEAVE THE H...

Page 9: ... way to purchase kerosene is in a pre packaged metal or plastic blue colored container The second choice would be to buy it from a dealer who stores it in a 55 gallon drum The third choice is to buy kerosene from a dealer who stores it in a large underground or above ground tank Kerosene that is contaminated with even a small amount of water will prevent a kerosene heater from functioning properly...

Page 10: ...you loosen counter clock wise the cap on the siphon pump to drain throughly the remaining kerosene in the siphon pump For the reuse of siphon pump make sure that you tighten clock wise the cap on the siphon pump to transfer the kerosene into the fuel tank properly Fig 8 IMPORTANT NOTICE REGARDING FUELING OF THE HEATER When fueling your heater for the first time and any other time when the tank has...

Page 11: ... match Fig 12 The procedure is as follows Turn the wick adjuster knob clockwise until the wick has been raised to its maximum height Lift the burn chamber by using the burner knob Touch a lighted match to the exposed top edge of the wick Once you see that the wick has been lit lower the burn chamber back down over the wick Rotate the burner knob from side to side a few times to make sure that the ...

Page 12: ...ick adjuster knob to obtain the proper flame height The proper flame height is a 1 2 flame above the center flame spreader disk with even distribution of flame around the flame spreader disk visible through the glass cylinder of the heater See pictures below for reference As you continue to operate the heater the temperature of the heater and the temperature of the room will continue to change As ...

Page 13: ...r type vacuum cleaner may be a useful tool in removing this ash Step 2 The first step should remove most carbon and your wick should feel softer to the touch If any part still feels hard you can use small pliers to pinch these hard spots and break up the carbon into pieces After doing this replace the cabinet add a small amount of fuel wait at least one hour and then repeat step 1 Carry out Carbon...

Page 14: ...t Knob COUNTERCLOCKWISE in the direction of OFF 3 Tilt slightly and lift up the Cabinet Grill assembly using both hands and lift away from the heater 2 Use screwdriver to loosen and remove 3 screws that fix cabinet base to fuel tank Remove the Wick Adjuster Knob and Ignition Knob Fig A Fig B WICK REPLACEMENT The wick in your heater needs replacing if after repeated cleanings any of the following c...

Page 15: ...ed grooves of the wick adjuster allowing the wick do drop slightly Once the pins line up with each hole press firmly on each pin toward the slanted grooves securely through each hole 11 1 Turn the wick adjustment knob to the fully raised position 2 Pull lightly on the skirt of the wick to remove any slack 3 Press lightly to secure the skirt to the retaining and remove any slack 4 You will need to ...

Page 16: ...al steps 18 Fasten the Cabinet Grill assembly to the heater with 3 screws Replace the Wick Adjuster Knob and ignition Knob to the heater 15 Check for correct clearance between wick holder and draft tube It should be the same all around 17 Tilt the Cabinet Grill assembly slightly using both hand and replace on heater from front to rear 16 Check the function of safety shut off mechanism by pushing t...

Page 17: ... wick and to replace the wick when necessary in order to prevent the build up of carbon and tar from creating a dangerous situation where the heater does not fully extinguish AUTOMATIC SAFETY SHUT OFF DEVICE This heater is equipped with an automatic safety shut off device The purpose of this device is to quickly and efficiently shut off the heater should the heater be jarred or tipped over while i...

Page 18: ...nse the inside of the tank NEVER mix water with the kerosene as it will cause rust inside the tank Pour the kerosene out making sure that you remove it all With the fuel tank empty ignite the heater With the wick at its maximum height keep the wick burning until it burns out completely about 1 hour It is a good idea to do this outside or in an extremely well ventilated area Remove the batteries Re...

Page 19: ...erosene gasoline benzene alcohol white gas paint thinner camp stove fuel oil compound 1 Drain and clean tank Remove and replace wick Fill tank with 1 K kerosene Wick Adjuster Sticks 1 Water present in kerosene 2 Carbon or tar built up 1 Drain tank Remove wick assembly replace wick Reinstall wick assembly Fill tank with 1 K kerosene 2 Perform Carbon Removal Dry Burning procedure Replace wick if nec...

Page 20: ...00 SeeSpecsBelow 3111 0291 00 3121 0509 01 3111 0292 00 2112 0043 00 3111 0293 01 3561 0073 00 3631 0021 00 3111 0295 01 2114 0021 01 2114 0022 01 2114 0023 01 3561 0074 01 3111 0245 00 PARTS LIST EXPLODED PARTS DRAWING DESCRIPTION DRAWING NUMBER PART NUMBER NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING SPECIFICATIONS Model No Type of...