15
h.
Referring to the illustrations below feed the cables through the two loose cable clamp brackets. The adjuster and lock screw can now
be fitted onto the cable and through the large hole in the cable clamp bracket. Position the brackets one either side of the fire towards
the bottom of the channel between the Main Casing and the Inner Fire Casing. By use of the adjuster and lock screw tighten up the
cable to tension the fire back into the fireplace. The fire should be secure and not liable to movement.
Surplus fixing cable MUST NOT
be cut off and must be tucked back through the small hole in the cable clamp bracket to keep it well away from any electronics.
i.
If any of the silicone sealing strips are not compressed and/or if there are gaps they must be filled with a suitable sealant, fireclay or
high temperature silicone.
j.
Refit the burner mounting plate assembly by first putting the Receiver through the opening then tilt the assembly and slide it into
the fire and secure with the 4 screws. Take care not to mark the liners in the fire. Place the Receiver to the left side at the front.
k.
Connect the isolation/pressure test elbow to the control valve and with it fully open check the joint for gas soundness.
l.
Check that all gas connections are sound. The appliance has been factory tested; however the connections may have been
disturbed in transit or storage.
! IMPORTANT NOTE !
Always reseal the pressure test point and check that it is gas tight.
(This accounts for a lot of recalls.)
BUILDERS OPENING – HOLE CENTRES
FOR CABLE FIXING SYSTEM EYEBOLTS
NOTE: Tensioning
nut wound fully back
to allow maximum
adjustment
FINISHED & ADJUSTED
Do not over tighten -
just enough to seal
30mm non-combustible lip/shelf
Referred to in section 13.1