6-4. OPERATION OF THE SERVO KEY UNIT
A built-in servo key unit provides the cost-effective and convenient editing function without optional
loader. When the servo amplifier is in servo-off, It is possible to enter the servo parameter mode by
the servo key unit. Editing sequence is as follows.
Operation
Push the MODE key to change from "status display"
to mode selection level.
1. The pre-saved mode is displayed at LED.
Each modes are scrolled sequentially by UP/DOWN
key.
2. Select the "PAr" mode and push the SET key.
3. The start no. of servo parameter is displayed.
Each parameter no. is scrolled sequentially by
UP/DOWN key. (P-00 ~ P-15)
Stop the display at the parameter no. to be
changed.
If you push the MODE key, the system returns to
the run ready state.
4. The pre-saved setting values are displayed by SET
key. The dots are displayed at the each LED.
5. Select the figure of LED sequentially by DOWN
key. The value of selected figure is blinking.
6. Push the UP key, the value of selected figure
is increased 1 by 1 as the ring counter.
If the value changed, the dots are disappeared.
Repeat the operation of 5 and 6.
For the cancellation of the changing value, push
the MODE key then return to the level 3.
7. Push the SET key to save the setting values.
If the setting values are out of ranges, they are
saved with limited value (max. or min. value).
8. Push the MODE key and return to the level 3.
The parameter no. is auto-increased 1 by 1.