CHAPTER 5. SETUP PARAMETER MODE
5-1. DEFINITION OF SETUP PARAMETER
Setup means the act of input the basic information about mechanical system (parameter) into controller
by the manufacturer of the system. Therefore, users must be careful when they want to change the
setup parameters. For the trouble shooting and maintenance, the setting value of parameters are in
need of document recording.
5-2. SELECTION OF SETUP PARAMETER MODE
If you push the button "SHIFT+F3" in run ready state, you can select the setup parameter mode in the
following display. It makes the servo amplifier to be automatically servo-off.
0 0 - F I L E # - + 0 0 0 0 0 0
0 1 - B S S P D - + 0 0 1 0 0 0
< Setup parameter edit mode>
━━
━━━━━
━
━━━━━
No.
Name
Sign Setting value
No.
: Setup parameter no. (00~79)
Name : Setup parameter name
Sign
: Sign of setting value
Value : Setting value
5-3. OPERATION OF THE LOADER
A. Screen shift
The cursor ( ) on the screen moves up and down if you push the button
_
UP, DOWN ( , )
↑ ↓ on the
front panel. When the cursor (
) is on the first row, the screen is up if you push button UP ( ).
_
↑
When the cursor (
) is on the second row, the screen is down if you push button DOWN ( ).
_
↓
For notifying the last setup line to the user, the screen displays as follows.
7 9 - X X X X X - + 0 0 0 0 0 0
< < E N D
O F
F I L E > >
< The last line >
B. Selection of the set-up number
The screen displays the contents of selected setup number if the desired number is typed when the
cursor is placed at the first letter of the number by using the button LEFT, RIGHT ( , )
← → .
C. Input of the setup value
If the cursor is placed at the 'Sign' position and the sigh button (
, ) is pushed, the present
+ -
value is cleared and the cursor is placed at the first of the value position (6 figures). If you enter
the desired number of value (data) and push ENTER
ꡒ
ꡓ
button at this state, the value is memorized
and the cursor is down to the next row. If the value is out of the allowed range, the data cannot
be entered and the cursor returns to the 'Sign' position. In case the input number is wrong, move
the cursor to the desired position and input the right number again. A button "SHIFT BACK"
+
is
used for the function of backspace. For the cancellation of the changing value, push the button
"SHIFT CANCEL"
+
then return to the original value.
D. Return to the run ready state
If you push the button "ESC", the system returns to the run ready state.
At this time, all setup parameters are saved into the memory. Therefore, never power off before
return to the run ready state.
Summary of Contents for Tango-B series
Page 68: ......
Page 111: ...APPENDIX ...