Site Information Editor - Baseline Sensor Information Parameters
These parameters are found on the right side of the Site Information Editor window.
Channel
Reports the logger channel for which the sensor information is being displayed. Use the up and down
arrows to scroll to the desired channel.
Load Defaults
To the right of the Channel # field, the Load Defaults button can be used to load a default scale factor
and offset for the type of sensor shown in the Sensor Type field (see below). Note that you will see
transfer functions (scale factors) in both SI and Imperial units, allowing the user to specify which units
are used for individual channels.
Description
Enter up to a 20-character sensor description. For NRG Systems sensors, this is the same as the sensor
model.
Details
Enter up to 80 characters in this field for reporting any sensor details.
Serial Number
A sensor serial number of up to 8 characters can be entered here.
Sensor Type
The sensor type and therefore the logging mode of the logger for this channel can be chosen using a
pull-down menu to the right of the Serial Number field. For a counter channel, the sensor type can be
either frequency (Speed), totalizer (Total), or Unknown. For flex channels, the sensor type can be
defined as either Unknown, Speed, Total, Vane, or Analog. For analog channels, the sensor type can be
defined as either Unknown, Vane, or Analog.
Height
Enter the sensor height in this field.
Scale Factor
A numerical sensor scale factor up to 8 characters is entered here.
Offset
A numerical sensor offset up to 8 characters is entered here.