NRG USER MANUAL
SymphoniePLUS3 User Guide
SymphoniePLUS3_DataLogger_Manual
Rev. 17
[email protected] | Page 29
31 December 2018
Site Latitude and Longitude (optional)
-
Press [Home] [4] [3] [5] to set site latitude.
-
Use the [Up] [Down] navigation keys to toggle between north and south (“N” and “S”), and use
the keypad to edit the displayed latitude information.
-
When the latitude information appears as desired, press [SET].
-
Use the [Up] [Down] navigation keys to toggle between east and west (“E” and “W”), and use the
keypad to edit the displayed longitude information.
-
When the longitude information appears as desired, press [SET].
-
Enter latitude and longitude in decimal degrees (rather than degrees, minutes, seconds)
-
If an iPackGPS with adequate GPS signal is connected to the logger, this setting will be updated
automatically at the end of a successful call.
-
With an iPack connected and using the programming adapter in the logger’s iPack access port, you
may set the Latitude and Longitude using SDR’s Logger Direct Editor screen (found in the File
menu of the Modify iPack Settings screen).
Data Encryption PIN (optional)
As a security measure, SymphoniePLUS3 can encrypt data before storing it on the SD card. A Data
Encryption PIN can be entered into the logger to enable data encryption. This is an optional feature
intended only for those for whom data theft is a risk. Data encryption can be disabled by setting the
PIN to 0000. The data encryption PIN is set to 0000 (disabled) by default. If the data are encrypted, then
the encryption PIN will also be needed for SDR to decrypt the data.
Do not lose the Data Encryption PIN! You must know the PIN in order to disable or change it.
Keypad Security (optional)
As an added security measure, SymphoniePLUS3 allows you to set a 6 digit lockout code for the logger’s
keypad. When a key is pressed, the first screen displayed will be:
NRG Systems, Inc.
SymphoniePLUS3
SN: 00000
Enter Security Key
Failure to enter the correct security key will result in a message:
NRG Systems, Inc.
SymphoniePLUS3
SN: 00000
Locked, 7 tries left
If the correct security key isn’t entered during one of the remaining attempts, the keypad will lock out
the user for approximately 2 days. Note that this is an optional feature intended only for use by those