
30
Novell Business Continuity Clustering 1.1 for NetWare Administration Guide
no
vd
ocx (
e
n)
1
1
Decemb
er
2
007
The container where the server objects reside.
If server objects reside in multiple containers, this must be a container high enough in the tree
to be above all containers that contain server objects.
Best practice is to have all server objects in one container.
The container where the cluster pool and volume objects will be placed when they are
synchronized to this cluster. This container is referred to as the landing zone. The NCP server
objects for the virtual server of a BCC enabled resource will also be placed in the landing zone.
If the eDirectory replica does not have read/write access to the containers listed above,
synchronization will not work properly.
NOTE:
Filtered eDirectory replicas are not supported with this version of Business Continuity
Cluster software. Full replicas are required.
To configure the IDM drivers/templates:
1
Start your Internet browser and enter the URL for iManager.
The URL is http://
server_ip_address
/nps/iManager.html. Replace
server_ip_address
with the
IP address or DNS name of the NetWare server that has iManager and the DirXML
preconfigured templates for iManager installed.
2
Enter your username and password.
3
In the left column, click
DirXML Utilities
, then click the
New Driver
link.
4
Choose to place the new driver in a new driver set, then click
Next
.
Both the User Object Synchronization Driver and the Cluster Resource Synchronization Driver
can be added to the same driver set.
5
Specify the driver set name, context, and the server that the driver set will be associated with.
The server is the same server where you installed the IDM engine and eDirectory driver.
6
Choose to
not
create a new partition for the driver set, then click
Next
.
7
Choose to import a preconfigured driver from the server, select the DirXML preconfigured
template for cluster resource synchronization, then click Next.
The template name is BCCClusterResourceSyncronization.XML.
8
Fill in the values on the wizard page as prompted, then click
Next
.
Each field contains an example of the type of information that should go into the field.
Descriptions of the information required are also included with each field.
Additional information for the wizard page fields includes:
Driver name:
Specify a unique name for this driver that will identify its function. For
example, Cluster1SyncCluster2. If you use both preconfigured templates, you must
specify different driver names for each driver template.
Name of SSL Certificate:
If you do not have an SSL certificate, leave this value set to the
default. The certificate will be created later in the configuration process. See
Step 1 on
page 32
for instructions on creating SSL certificates.
DNS name of other IDM node:
Specify the DNS name or IP address of the IDM server
in the other cluster.