Installation Manual
Technical Specifications
Version 3.0
189
Power:
MX500 CDU :
Type:
DC/ DC switch mode with galvanic
separation
Consumption:
Less than 11W (display back light
on). Typical 8W at 24 volt external
supply voltage. Typical 8.7W at 12
volt external supply voltage
Supply voltage:
12 or 24 volt battery: 10.5 to 32 VDC
Reverse protection:
-100 volt: internal diode
Over voltage protection:
+40 volt: fuse and transient voltage
suppression
Fuse: Internal over current / over tempera
-
ture fuse. Automatic resetting
Insulation:
Supply voltage to data pins or shield:
Maximum 50 VDC
Antenna supply:
12 VDC, maximum 500mA
Antenna
:
MX 521:
12 VDC, 200 mA
MX 421B:
12 VDC, 280 mA
MX 525:
12 VDC, 200 mA
MX500 CDU Inputs and Outputs:
The input and output circuits of the serial interfaces meet the require-
ments of:
•
IEC 61162-1
including the requirements of
ITU-T V.11
.
•
NMEA 0183
version 1.5, 2.0, 2.1, 2.2 & 2.3
NMEA talker
(all outputs):
Levels:
Maximum ±6 volt, minimum ±2
volt, A out relative to B out
Current:
Minimum 15mA
Protection:
-1 volt to +6 volt, output relative to
shield, ±50 volt, output relative to
external power lines
NMEA listeners
(all inputs):
Insulation:
Opto-coupler. Maximum ±50 volt,
input relative to shield or power
supply lines
Summary of Contents for MX500
Page 1: ...oOperator s Installation Manual MX500 Navigation System ...
Page 14: ...Version 3 0 ix Table of Contents Operator s Manual ...
Page 165: ...Version 3 0 151 Configuration Operator s Manual ...
Page 167: ...Version 3 0 153 Datum List Operator s Manual ...
Page 195: ...List of Components Installation Manual Version 3 0 181 APPENDIX F INSTALLATION SECTION ...
Page 196: ...Installation Manual List of Components 182 Version 3 0 SECTION 1 LIST OF COMPONENTS ...
Page 219: ...Installation Notes Version 3 0 205 Installation Manual SECTION 5 INSTALLATION NOTES ...
Page 282: ......
Page 283: ......