![Nortek 2GIG GC3 Installation And Programming Manual Download Page 63](http://html.mh-extra.com/html/nortek/2gig-gc3/2gig-gc3_installation-and-programming-manual_1705961063.webp)
Copyright © 2019 Nortek Security & Control LLC
63
Q54: AC restore reports to CS
Con
fi
gures the system to transmit a report to the Central
Station when AC power is restored to the GC3 Panel.
When enabled, AC power must be restored for one (1)
minute before the trouble condition clears from the system.
You have these options:
»
† Enabled: The system transmits a report to the
Central Station. If “Q47: Random AC loss report
time” above is enabled, the report will be sent at
a random time up to 45 minutes after the trouble
conditions clears.
»
Disabled: The system does not transmit a report to
the Central Station.
Q55: System low battery reports to CS
Con
fi
gures the system to transmit low battery reports about
the GC3 Panel to the Central Station.
Choose one of these options:
»
† Enabled: The system transmits a report to the
Central Station.
»
Disabled: The system does not transmit a report to
the Central Station.
Q56: System low battery restore reports to CS
Con
fi
gures the system to transmit a report to the Central
Station after a low battery condition on the GC3 Panel is
restored.
Choose one of these options:
»
† Enabled: The system transmits a report to the
Central Station.
»
Disabled: The system does not transmit a report to
the Central Station.
Q57: RF low battery reports to CS
Con
fi
gures the system to transmit low battery reports
about the system’s sensors and peripherals to the Central
Station.
Choose one of these options:
»
† Enabled: The system transmits a report to the
Central Station.
»
Disabled: The system does not transmit a report to
the Central Station.
Q58: Sensor low battery restore reports to CS
Con
fi
gures the system to transmit a report to the Central
Station after a low battery condition for a sensor is restored.
Choose one of these options:
»
† Enabled: The system transmits a report to the
Central Station.
»
Disabled: The system does not transmit a report to
the Central Station.
Q59: System disarmed reports to CS
Con
fi
gures the system to transmit a report to the Central
Station when the system is disarmed by a user. The report
includes the keyfob or user code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the
Central Station.
»
† Disabled: The system does not transmit a report to
the Central Station.
Q60: System armed reports to CS
Con
fi
gures the system to transmit a report to the Central
Station when the system is disarmed by a user. The report
includes the keyfob or user code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the
Central Station.
»
† Disabled: The system does not transmit a report to
the Central Station.
Q61: Alarm restore reports to CS
Con
fi
gures the system to transmit reports to the Central
Station after an alarm, either when the Bell Cutoff Time
expires or when the system is disarmed.
You have these options:
»
Enabled: The system transmits a report to the
Central Station. Depending on the number of trips
set for a cross sensor zone, the feature works as
follows:
»
If enabled and “Q25: “ on page 1 is set to two
(2) trips, the system transmits a report when the
triggering sensor is closed (i.e., in its normal
state) at the Bell Cutoff Time or if the sensor is
closed after the Bell Cutoff Time.
»
If enabled and “Q25: “ on page 1 is set to one
(1) trip, the system transmits a report only if
the sensor is closed at the time the system is
disarmed. Reports are not sent if a sensor is in
swinger shutdown until the time of disarm and
the sensor is closed.
»
† Disabled: The system does not transmit a report to
the Central Station.