Technical Data
8-2
Part 1024496_06
2014
Nordson Corporation
Electrical Specifications
Item
Data
Note
Hose/gun heating capacity
2, 4, or 6 hose/gun pairs
A
Control temperature range
40 to 230
C (100 to 450
F)
Control temperature accuracy
1
C
B
International Protection (IP) rating
IP54
Input voltage tolerance
+10%, -15%
NOTE
A:
Dependent on melter configuration and addition of optional hose/gun modules
B:
Flow set-point at RTD
Pump Specifications
Item
Data
Air pressure while running
70 to 689 kPa (10 to 100 psi)
Minimum air pressure
0.7 bar (10 psi)
Viscosity range
800 to 10,000 cps
Maximum hydraulic pressure
15:1 pump: 10.3 MPa (1500 psi)
6:1 pump: 4.14 MPa (600 psi)
Air consumption at 415 kPa (60 psi) and maximum pump
speed
46 l/min. (1.6 scfm)
Displacement
7.20 ml/stroke ( 0.44 in
3
/stroke)
Maximum speed
90 strokes/min.
Melter Power Requirements
Melter
Number of
Hose/Guns
1‐Phase Power
Draw (Amps)
3‐Phase Power (Amps)
Without Neutral
With Neutral
P4
2
17
15
9
4
26
23
17
P7
2
18
16
10
4
27
24
17
P10
2
18
16
10
4
27
24
17
6
35
31
18
Summary of Contents for ProBlue P10
Page 10: ...Table of Contents viii Part 1024496_06 2014 Nordson Corporation...
Page 22: ...Safety 1 12 2014 Nordson Corporation Issued 10 11...
Page 37: ...Installation 3 7 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 53: ...Installation 3 23 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 61: ...Installation 3 31 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 65: ...Installation 3 35 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 69: ...Installation 3 39 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 78: ...Installation 3 48 Part 1024496_06 2014 Nordson Corporation...
Page 108: ...Operation 4 30 Part 1024496_06 2014 Nordson Corporation...
Page 125: ...Troubleshooting 6 7 Part 1024496_06 2014 Nordson Corporation Figure 6 1 Electrical components...
Page 138: ...Troubleshooting 6 20 Part 1024496_06 2014 Nordson Corporation Figure 6 6 Removing the pump...
Page 170: ...Parts 7 6 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 177: ...Parts 7 13 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 181: ...Parts 7 17 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 212: ...Technical Data 8 8 Part 1024496_06 2014 Nordson Corporation...
Page 213: ...Technical Data 8 9 Part 1024496_06 2014 Nordson Corporation...
Page 214: ...Technical Data 8 10 Part 1024496_06 2014 Nordson Corporation...
Page 215: ...Technical Data 8 11 Part 1024496_06 2014 Nordson Corporation...
Page 216: ...Technical Data 8 12 Part 1024496_06 2014 Nordson Corporation...
Page 217: ...Technical Data 8 13 Part 1024496_06 2014 Nordson Corporation...
Page 218: ...Technical Data 8 14 Part 1024496_06 2014 Nordson Corporation...
Page 219: ...Technical Data 8 15 Part 1024496_06 2014 Nordson Corporation...
Page 220: ...Technical Data 8 16 Part 1024496_06 2014 Nordson Corporation...
Page 224: ...Calculating Melter Power Requirements A 4 Part 1024496_06 2014 Nordson Corporation...
Page 248: ...Operating Parameters B 24 Part 1024496_06 2014 Nordson Corporation...
Page 260: ...Melter Communications C 12 Part 1024496_06 2014 Nordson Corporation...
Page 315: ...400 480 Volt ProBlue Adhesive Melters E 21 Part 1024496_06 2014 Nordson Corporation...
Page 318: ...400 480 Volt ProBlue Adhesive Melters E 24 Part 1024496_06 2014 Nordson Corporation...