Melter Faults
Table 6‐1 lists the four types of melter faults, potential causes, and expected
corrective actions.
Table 6‐1 Melter Faults
Display
Code/Sub‐code
Name
Affect on Melter
Cause
Corrective Action
F1/None
RTD
Heaters turn off
The RTD for the
component indicated
has failed or the
component was
disconnected from
the melter.
Replace RTD
Check hose/gun
connections
See flowchart T.2
F2/None
Under
temperature
Heaters turn off
The actual temperature
of the component
indicated has dropped
below the under
temperature delta,
which was set using
parameter22.
Check for conditions
that may cause a drop
in ambient temperature
Raise the set‐point
temperature of the
component
Replace RTD
See flowchart T.2
F3/None
Over temperature
Heaters turn off
The actual temperature
of the component
indicated has increased
beyond the over
temperature delta,
which was set using
parameter21.
Replace RTD
See flowchart T.2
F4/1
RAM test
Melter stops
functioning
Internal RAM failure
Replace CPU
F4/2
Internal Clock
time
Heaters remain on,
but fault condition
persists
Internal clock failure
Replace CPU
F4/4
Internal clock
battery backed
RAM
Heaters remain on,
but fault condition
persists
Battery‐backed RAM
failure
Replace CPU
F4/5
Internal clock
battery
Heaters remain on,
but fault condition
persists
Battery‐backed RAM
battery dead
Replace CPU
F4/6
Analog‐to‐digital
Melter stops
functioning
RTD analog‐to‐digital
converter failed
Replace main board or
CPU
Continued...
Summary of Contents for ProBlue P10
Page 10: ...Table of Contents viii Part 1024496_06 2014 Nordson Corporation...
Page 22: ...Safety 1 12 2014 Nordson Corporation Issued 10 11...
Page 37: ...Installation 3 7 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 53: ...Installation 3 23 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 61: ...Installation 3 31 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 65: ...Installation 3 35 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 69: ...Installation 3 39 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 78: ...Installation 3 48 Part 1024496_06 2014 Nordson Corporation...
Page 108: ...Operation 4 30 Part 1024496_06 2014 Nordson Corporation...
Page 125: ...Troubleshooting 6 7 Part 1024496_06 2014 Nordson Corporation Figure 6 1 Electrical components...
Page 138: ...Troubleshooting 6 20 Part 1024496_06 2014 Nordson Corporation Figure 6 6 Removing the pump...
Page 170: ...Parts 7 6 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 177: ...Parts 7 13 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 181: ...Parts 7 17 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 212: ...Technical Data 8 8 Part 1024496_06 2014 Nordson Corporation...
Page 213: ...Technical Data 8 9 Part 1024496_06 2014 Nordson Corporation...
Page 214: ...Technical Data 8 10 Part 1024496_06 2014 Nordson Corporation...
Page 215: ...Technical Data 8 11 Part 1024496_06 2014 Nordson Corporation...
Page 216: ...Technical Data 8 12 Part 1024496_06 2014 Nordson Corporation...
Page 217: ...Technical Data 8 13 Part 1024496_06 2014 Nordson Corporation...
Page 218: ...Technical Data 8 14 Part 1024496_06 2014 Nordson Corporation...
Page 219: ...Technical Data 8 15 Part 1024496_06 2014 Nordson Corporation...
Page 220: ...Technical Data 8 16 Part 1024496_06 2014 Nordson Corporation...
Page 224: ...Calculating Melter Power Requirements A 4 Part 1024496_06 2014 Nordson Corporation...
Page 248: ...Operating Parameters B 24 Part 1024496_06 2014 Nordson Corporation...
Page 260: ...Melter Communications C 12 Part 1024496_06 2014 Nordson Corporation...
Page 315: ...400 480 Volt ProBlue Adhesive Melters E 21 Part 1024496_06 2014 Nordson Corporation...
Page 318: ...400 480 Volt ProBlue Adhesive Melters E 24 Part 1024496_06 2014 Nordson Corporation...