Operating Parameters
B-16
Part 1024496_06
2014
Nordson Corporation
Seven‐day Clock
(contd)
50
Current Day
Description:
Used to set the current day of the week.
Value:
1 to 7 (1 = Monday, 2 = Tuesday, etc.)
Resolution:
1
Default Value:
—
Format:
—
Use:
Refer to Section 4,
Operation, Using Melter Function Keys
,
for
information about the use and affects of the seven-day clock feature.
51
Current Hour
Description:
Used to set the local time of the day.
Value:
0000 to 2359 (European time format)
Resolution:
1 minute
Default Value:
(Time set at factory)
Format:
Hours, Hour: Minute, Minute
Use:
This setting only needs to be made once for all daily schedules
55
Schedule 1 Heaters On
Description:
Used to set the time that the clock will turn on the heaters during
schedule 1.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
0600
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn on.
To disable this parameter, set the parameter’s value to “- - - -” by
simultaneously pressing both of the right-display scroll keys.
56
Schedule 1 Heaters Off
Description:
Used to set the time that the clock will turn off the heaters during
schedule 1.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
1700
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn off.
To disable this parameter, set the parameter’s value to “- - - -” by
simultaneously pressing both of the right-display scroll keys.
Summary of Contents for ProBlue P10
Page 10: ...Table of Contents viii Part 1024496_06 2014 Nordson Corporation...
Page 22: ...Safety 1 12 2014 Nordson Corporation Issued 10 11...
Page 37: ...Installation 3 7 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 53: ...Installation 3 23 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 61: ...Installation 3 31 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 65: ...Installation 3 35 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 69: ...Installation 3 39 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 78: ...Installation 3 48 Part 1024496_06 2014 Nordson Corporation...
Page 108: ...Operation 4 30 Part 1024496_06 2014 Nordson Corporation...
Page 125: ...Troubleshooting 6 7 Part 1024496_06 2014 Nordson Corporation Figure 6 1 Electrical components...
Page 138: ...Troubleshooting 6 20 Part 1024496_06 2014 Nordson Corporation Figure 6 6 Removing the pump...
Page 170: ...Parts 7 6 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 177: ...Parts 7 13 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 181: ...Parts 7 17 Part 1024496_06 2014 Nordson Corporation This page intentionally left blank...
Page 212: ...Technical Data 8 8 Part 1024496_06 2014 Nordson Corporation...
Page 213: ...Technical Data 8 9 Part 1024496_06 2014 Nordson Corporation...
Page 214: ...Technical Data 8 10 Part 1024496_06 2014 Nordson Corporation...
Page 215: ...Technical Data 8 11 Part 1024496_06 2014 Nordson Corporation...
Page 216: ...Technical Data 8 12 Part 1024496_06 2014 Nordson Corporation...
Page 217: ...Technical Data 8 13 Part 1024496_06 2014 Nordson Corporation...
Page 218: ...Technical Data 8 14 Part 1024496_06 2014 Nordson Corporation...
Page 219: ...Technical Data 8 15 Part 1024496_06 2014 Nordson Corporation...
Page 220: ...Technical Data 8 16 Part 1024496_06 2014 Nordson Corporation...
Page 224: ...Calculating Melter Power Requirements A 4 Part 1024496_06 2014 Nordson Corporation...
Page 248: ...Operating Parameters B 24 Part 1024496_06 2014 Nordson Corporation...
Page 260: ...Melter Communications C 12 Part 1024496_06 2014 Nordson Corporation...
Page 315: ...400 480 Volt ProBlue Adhesive Melters E 21 Part 1024496_06 2014 Nordson Corporation...
Page 318: ...400 480 Volt ProBlue Adhesive Melters E 24 Part 1024496_06 2014 Nordson Corporation...