System Setup
3-17
Part 1604857-04
E
2014 Nordson Corporation
Function Settings
To change functions, press the Plus or Minus buttons on the kV/
A panel.
To change function values press the Plus or Minus buttons on the Flow Air
panel.
Function No.
Name
Settings
Default
1
Gun Type
0 = Encore
0
2
Fluidizing
0 = Hopper, 1 = Box, 3 = Disable
0
3
Electrostatic Control
0 = Custom, 1 = Classic, 2 = NFC
0
4
Powder Flow Control
0 = Smart, 1 = Classic
0
5
Cable Length
0 = 6 meters, 1 = 12 meters, 2 = 18 meters
0
6
Vibratory Box Delay
on, 0
−
90 seconds
30
NOTE:
Refer to the Operation section for explanations of the differences in
Electrostatic Control and Powder Flow Control modes.
Vibratory Box Feeder Settings
Continuous Operation
To set the vibrator motor to continuous operation, choose the “on” setting. In
this mode, the vibrator motor turns on when the gun is first triggered and
stays on until you press the Enable/Disable button or turn off system power.
Shut Off Delay
If you set a delay time, the vibrator motor turns on when the gun is triggered
and stays on for the delay time after the trigger is released. This setting is
designed to prevent chattering (rapid on/off cycling) of the vibrator motor
during production and extends the life of the motor. Adjust the delay as
required for your application.
Exiting Configuration Mode
To accept all function values and exit Configuration Mode, press the
Enable/Disable button. The controller can now be operated normally.
Summary of Contents for Encore LT
Page 4: ...Change Record ii Part 1604857 04 E 2014 Nordson Corporation ...
Page 12: ...Safety 1 4 Part 1604857 04 E 2014 Nordson Corporation ...
Page 34: ...System Setup 3 18 Part 1604857 04 E 2014 Nordson Corporation ...
Page 56: ...Troubleshooting 5 8 Part 1604857 04 E 2014 Nordson Corporation ...
Page 68: ...Repair 6 12 Part 1604857 04 E 2014 Nordson Corporation ...
Page 86: ...Parts 7 18 Part 1604857 04 E 2014 Nordson Corporation ...
Page 87: ...Wiring Diagram 8 1 Part 1604857 04 E 2014 Nordson Corporation Section 8 Wiring Diagram ...
Page 88: ...Wiring Diagram 8 2 Part 1604857 04 E 2014 Nordson Corporation ...
Page 92: ...ZONE REV DESCRIPTION BY CHK RELEASE NO DATE SEE SHEET 1 FOR REVISION HISTORY ...