System Setup
3-13
Part 1604857-04
E
2014 Nordson Corporation
Bundling Tubing and Cable
Use the sections of black spiral-cut tubing supplied with the system to
bundle together the spray gun cable, air tubing, and powder hose. Coil the
bundled tubing and cable and hang the coil on the hook at the back of the
cart tower.
System Air Connections
System Air Supply
Compressed air should be supplied from an air drop equipped with a
self-relieving shutoff valve. The air must be clean and dry. A refrigerant or
desiccant-type air drier and air filters are recommended.
All systems are shipped with a 0.3-micron air filter. It is important that the
filter be used to prevent contamination of the system pneumatic
components and the powder supply.
Supply air pressure should be 4.0
−
7.6 bar (58
−
110 psi).
To provide air to your system, an input air kit with connectors, couplings,
and 10-mm air tubing (15-ft for dolly systems, 25-ft for wall/rail mount
systems) is available.
Refer to the
Parts
section for filter kits, replacement elements, and input air
kit part numbers and ordering information.
Mobile Systems
Connect 10-mm air tubing from your compressed air supply to the air input
fitting on the rear panel of the dolly.
Wall/Rail Mount Systems
1. Use the mounting bracket (4) as a template to mark and drill mounting
holes in the selected mounting surface. Make sure there is sufficient
clearance to connect air tubing and change the filter element.
2. Install the two male connectors (2) included in the kit in the filter input
and output ports.
3. Install the mounting bracket on the filter, using the included M5 screws
(3), on the side of the filter opposite the release latch (6).
4. Mount the filter with customer-supplied fasteners (7).
5. Note the orientation of the flow indicator (5) on the top of the filter. Cut
10-mm blue air tubing to the required lengths to connect the air supply
to the filter and the filter to the controller, then connect the tubing.
Summary of Contents for Encore LT
Page 4: ...Change Record ii Part 1604857 04 E 2014 Nordson Corporation ...
Page 12: ...Safety 1 4 Part 1604857 04 E 2014 Nordson Corporation ...
Page 34: ...System Setup 3 18 Part 1604857 04 E 2014 Nordson Corporation ...
Page 56: ...Troubleshooting 5 8 Part 1604857 04 E 2014 Nordson Corporation ...
Page 68: ...Repair 6 12 Part 1604857 04 E 2014 Nordson Corporation ...
Page 86: ...Parts 7 18 Part 1604857 04 E 2014 Nordson Corporation ...
Page 87: ...Wiring Diagram 8 1 Part 1604857 04 E 2014 Nordson Corporation Section 8 Wiring Diagram ...
Page 88: ...Wiring Diagram 8 2 Part 1604857 04 E 2014 Nordson Corporation ...
Page 92: ...ZONE REV DESCRIPTION BY CHK RELEASE NO DATE SEE SHEET 1 FOR REVISION HISTORY ...