System Setup
3-15
Part 1604857-04
E
2014 Nordson Corporation
System Electrical Connections
Power Supply
CAUTION:
If you have a mobile system with a vibratory box feeder, check
the system identification plate for the correct voltage. Connecting a system
with a 115 Vac vibrator motor to 220 Vac could damage the vibrator motor.
The spray gun controller is rated for 100
−
240 Vac at 50/60 Hz, single phase,
and is marked as such, but the power supplied to the system must match
the vibrator motor rating.
Wire the system power cord to a customer-supplied three-prong plug.
Connect the plug to a receptacle that supplies the correct voltage.
Wire Color
Function
Blue
N (neutral)
Brown
L (hot)
Green/Yellow
GND (ground)
System Ground
Mobile Systems:
See Figure 3-15. Connect the ground cable attached to
the controller ground stud to a true earth ground.
Figure 3-15 System Ground Connection
Rail Mount Systems:
Locate the ESD grounding block kit. Follow the kit
instructions to install the grounding block to the grounded spray booth base.
Connect the flat braided ground cable from the controller ground stud to the
grounding block.
Summary of Contents for Encore LT
Page 4: ...Change Record ii Part 1604857 04 E 2014 Nordson Corporation ...
Page 12: ...Safety 1 4 Part 1604857 04 E 2014 Nordson Corporation ...
Page 34: ...System Setup 3 18 Part 1604857 04 E 2014 Nordson Corporation ...
Page 56: ...Troubleshooting 5 8 Part 1604857 04 E 2014 Nordson Corporation ...
Page 68: ...Repair 6 12 Part 1604857 04 E 2014 Nordson Corporation ...
Page 86: ...Parts 7 18 Part 1604857 04 E 2014 Nordson Corporation ...
Page 87: ...Wiring Diagram 8 1 Part 1604857 04 E 2014 Nordson Corporation Section 8 Wiring Diagram ...
Page 88: ...Wiring Diagram 8 2 Part 1604857 04 E 2014 Nordson Corporation ...
Page 92: ...ZONE REV DESCRIPTION BY CHK RELEASE NO DATE SEE SHEET 1 FOR REVISION HISTORY ...