Maintenance
7-3
Table 7-1 Routine Maintenance Procedures (Continued)
Task
Frequency
Instructions
Lubricate Mechanical
Drive Cables
Every three
months
.
Clean Camera Lens
Every three
months
Use the cleaning kit provided.
Tension Mechanical
Drive Cables
Every 6-12
months
Tension Conveyor Belts
As Needed
7.10 Tensioning the Conveyor Belts
Replace Conveyor Belts
As Needed
9.7 Replacing the Conveyor Belts
7.5 Replacing
Consumables
Consumables are items that are discarded and replaced on a regular basis. The following items are
common consumables and should be replaced at the intervals recommended in Table 7-1.
•
Purge Boots
•
Scale and Purge Cups
Tools and Materials Needed
•
Needle-nosed Pliers
•
Replacement Purge Boot (see Table 7-2)
•
Isopropyl Alcohol
•
Replacement 1 oz. (29 ml) Plastic Cups (P/N 58-0030)
•
Clean Shop Cloth
•
Small Brush
•
Rubber Gloves
•
Personal Protective Equipment (as required)
Table 7-2 Purge Boot Colors, Sizes, and Compatible Needles
Purge Boot Color
Inside Diameter
Compatible Needle Gages
Asymtek P/N
Orange
0.5 mm (0.020-in.) 26, 27, 30, 32
01-0019-00
Pink
0.8 mm (0.031-in.) 22, 23, 24, 25
01-0021-00
Green
1.1 mm (0.045-in.) 19, 20, 21
01-0018-00
Olive*
3.0 mm (0.120-in.) 14, 15, 16, 18
01-0022-00
*Recommended size for nozzles on DJ-2000 and DJ-9000 Series Dispensing Valves.
Summary of Contents for Asymtek Spectrum S-920
Page 2: ......
Page 4: ......
Page 30: ...1 14 Introduction 1 10 5 Rear View Figure 1 7A Rear View 2 3 4 1 5...
Page 124: ......
Page 185: ...Troubleshooting 8 11 Figure 8 3 FmXP Scale Setup Menu Figure 8 4 Scale Error Message...
Page 190: ......
Page 204: ......
Page 208: ......
Page 210: ......
Page 220: ......
Page 222: ......
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 234: ......