Troubleshooting
8-7
8.4.6 Height
Sensor
Table 8-6 Height Sensor Troubleshooting
Symptom
Possible Cause
Recovery
Probe is damaged
Check for bent probe. Replace if necessary. See
Replacing the Height Sensor Probe
No air pressure
Verify main air pressure is
ON (I)
.
Probe does not drop or
retract
Flow control improperly set
(closed to off) or there is a
pinched pneumatic line for the
height sensor.
Readjust the flow control located in the servo shelf by
opening it to ¾ open. Refer to the system pneumatic
diagram. Verify there is no kinked or pinched line from
the height sensor solenoid, through the cat track and to
the height sensor.
Main air pressure not set
properly
Readjust main air pressure regulator to system’s
nominal pressure.
Probe either drops too
slowly or slams down with
too much force
Flow control improperly set
Readjust the flow control located in the servo shelf.
Refer to the system pneumatic diagram.
Probe tip is lower than the
needle tip when valve is in
dispensing position.
Adjust probe and perform “Valve Offsets” in FmXP.
See
5.10 Adjusting the Height Sensor Probe
The Height Sensor is not set up
properly.
Test the height sensor. FmXP provides a height sensor
test utility from the tools, diagnostics menu. The probe
can be toggled up and down to verify probe
functionality. There is also a test procedure that
captures HS trigger values. FmXP can display a
statistical analysis of the captured values.
Needle hits substrate
HS velocity is set too high
Reduce the HS velocity to 2 inches per second and re-
run the valve offsets. Test the HS from the diagnostics
menu if necessary.
Safe Z-height too low
Reteach Safe Z-height. See
Probe hits substrate
before it is fully extended
Retract distance too low
Reteach the retract distance in the height sensor setup.
Refer to the
FmXP User Guide
or Online Help.
8.4.7 Laser Height Sensor
Table 8-7 Laser Height Sensor Troubleshooting
Symptom
Possible Cause
Recovery
Height sensor is not plugged in
Check power connection and verify that Height Sensor
plugged in.
Height Sensor does not
power up
Bad resistor on the main board
d-sub connection.
Use a multimeter to verify that the main board d-sub
resistor is good.
Dip switches not set properly
Verify that dip switch number 6 on SW1 on the Main
Board is set to on. See Figure 8-2.
Height sensor lens is dirty
Check and clean the Height Sensor lens.
Height Sensor does not
trigger
No communication with PC
Verify I/O tools can toggle height sensor bits.
Intermittent function
Loose or frayed cables
Check cables for tight connection and wear.
Summary of Contents for Asymtek Spectrum S-920
Page 2: ......
Page 4: ......
Page 30: ...1 14 Introduction 1 10 5 Rear View Figure 1 7A Rear View 2 3 4 1 5...
Page 124: ......
Page 185: ...Troubleshooting 8 11 Figure 8 3 FmXP Scale Setup Menu Figure 8 4 Scale Error Message...
Page 190: ......
Page 204: ......
Page 208: ......
Page 210: ......
Page 220: ......
Page 222: ......
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 234: ......