5-10
Calibration and Adjustment
5.10 Adjusting the Height Sensor Probe
The Height Sensor Probe must be adjusted each time a different type of dispensing valve or a different
length of needle is installed.
To adjust the Height Sensor Probe:
1.
Power down the system as described in
2.
Manually move the dispensing head down.
3.
Loosen the Height Sensor Probe locking screw at the back of the Z-axis plate.
See Figure 5-12.
4.
Move the probe to the desired location (approximately 10 mm below the needle tip in the
gear down position).
5.
Tighten the height sensor locking screw. Do not over-tighten.
Item Description
1
Z-Axis Plate (Front View)
2
Z-Axis Plate (Rear View)
3
Height Sensor Locking Screw
4
Height Sensor Probe
Figure 5-12 Adjusting the Height Sensor Probe
"
NOTE
For additional information on dispensing valve-to-height sensor offsets, see
3
4
1
2