Operation
6-29
To place a program command in a Conveyor Block:
1.
In the Fluidmove Main Window, select
Teach a Program
.
!
The Programming Window opens.
2.
Click on the
Conveyor
button on the Program Commands toolbar.
!
The Conveyor drop-down menu (Figure 6-24) opens.
Figure 6-24 Programming Window - Conveyor Block Commands
3.
Select
Use Conveyor 1 Block
or
Use Conveyor 2 Block
depending on where you want
to dispense.
!
A Conveyor Block command similar to the one below will be inserted into your program.
1
USE CONVEYOR 1:
2
END USE CONVEYOR:
4.
Move the cursor to the beginning of the
END USE CONVEYOR
command.
5.
Click on the
Dispense Elements
button on the Program Commands toolbar.
!
A Teach Window opens.
6.
Select the element you want to program from the Dispensing Elements toolbar and follow the
screen prompts.
7.
Click on
Done
when you are finished.
!
The dispensing command should be inserted between the
Use Conveyor 1
and
End Use Conveyor
commands.
8.
Save the program.
!
A sample program is shown in Figure 6-25.