Installation
3-2
E
1996 Nordson Corporation
All rights reserved
107 041A
Issued 1/96
Manual 12-28
An ideal oven installation is shown in
duct installation guidelines:
WARNING: To prevent exposure to potentially hazardous
exhaust vapors, each oven installed should be equipped with an
individual exhaust system. The exhaust duct should not be
connected to a common, existing factory exhaust system.
S
Install an independent air handling system that can provide
16.99 cmm @ 25.4 mm (600 cfm @ 1.0 inches) of water static
pressure at the oven exhaust port.
S
The distance between the exhaust duct and the oven exhaust should
not be less than 152.4 m (6 in.).
S
An ideal exhaust duct consists of an 203.2 mm (8 in.) diameter duct
rising from the floor to a roof mounted blower.
S
Install a U-shaped duct at the roof to prevent water from entering the
oven exhaust air handling system.
S
Adjust the pass line height for the in-line system specifications.
S
Wire the air handling exhaust blower to turn on simultaneously with
the oven blower. (For standalone use only)
S
The air handling exhaust blower must remain on for at least 5 minutes
after the oven blower turns off.
S
Use a dampening device to control exhaust air flow from the oven.
S
Install the dampening device 2.4 meters (8 ft) above the intersection
of the air handing exhaust duct and oven exhaust.
4. Exhaust Duct Installation
Guidelines
Summary of Contents for 107 041A
Page 1: ...Select Cure 100 Inch IR Oven Part 107 041A NORDSON CORPORATION D AMHERST OHIO D USA ...
Page 9: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 12 28s1 Section 1 Safety ...
Page 10: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 12 28s1 ...
Page 148: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 107 041A Issued 1 96 Manual 12 28 ...