Troubleshooting
6-6
E
1996 Nordson Corporation
All rights reserved
107 041A
Issued 1/96
Manual 12-28
Problem
Possible Cause
Corrective Action
5. Loss of 5.25 VDC voltage
Loss of 120 VAC to power supply
board
See Figures 6-1 and 6-2. Check for 120
VAC at power supply board terminal
block. If voltage is not present, perform
problem number 3. If voltage is present,
turn oven off and check for blown power
supply fuse or open wiring.
Bad power supply board or wiring
Turn oven off. Pull controller cards
away from card cage backplane about
2.5 cm (1 in.). Check for a short in wires
1099 and 1119 and power supply board.
Replace as necessary.
If no short is found, turn on oven.
Measure for 5.25 VDC at power supply
board’s output. If no voltage is
measured, replace board.
Bad controller card
Turn oven off. Install controller cards.
Turn oven on and measure for 5.25 VDC
at the power supply board’s output. If
voltage is present, check for a short on
5 VDC input of each controller card.
Replace shorted controller card(s).
WARNING: Hot! Risk of burns. Wear heat-protective clothing,
safety goggles with side shields and/or heat-protective gloves.
The following table contains trobleshooting procedure for the conveyor
speed control.
Power Supply Problems
(contd)
Conveyor Speed Control
Problems
Summary of Contents for 107 041A
Page 1: ...Select Cure 100 Inch IR Oven Part 107 041A NORDSON CORPORATION D AMHERST OHIO D USA ...
Page 9: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 12 28s1 Section 1 Safety ...
Page 10: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 12 28s1 ...
Page 148: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 107 041A Issued 1 96 Manual 12 28 ...