13
member the bracket is mounted onto.
Cable-tie the connector in place. The cable
must not be allowed to hang below the
boom (
Figure 6
).
Figure 6 – Another Acceptable Mounting
Avoid mounting sensors in
locations where they may read
from parts of the boom as shown in
Figure 7.
Figure 7 – Poor Mounting
(Sensor Reading off Boom)
General mounting rules for UC4+
ultrasonic sensors:
a)
In its lowest position, the sensor mouth
must be 9 inches or more from the
ground.
b)
The bottom of the sensor must be at
least 9 inches in front of the spray
nozzles.
c)
The bottom of the sensor must be at
least 9 inches above the spray nozzles.
d)
Ensure that there are no obstructions
within a 12-inch diameter circle
projected directly below the center of
the sensor.
e)
The sensor should be approximately
vertical at normal operating heights.
Figure 8 – Sensor Mounting Guidelines
Figure 9 - Wing Sensor Mounting
A
B
B
D
C
Ultrasonic
Acoustic Cone
Summary of Contents for UC4+
Page 12: ...9 Figure 3 Hydraulic Plumbing Schematic ...
Page 30: ...27 Figure 36 Load Sense Plumbing on some JD4710 Rear of Sprayer Front view of block H06 F03 ...
Page 32: ...29 Figure 38 2003 Load Sense Line Connection H06 F03 ...
Page 41: ...38 5 3 ITEM C3 44656D CABLE VALVE VARIABLE RATE DT ...
Page 42: ...39 5 4 ITEM C4 44651 VALVE EXTENSION CABLE 5 5 ITEM C10 44650 14 POWER CABLE ...
Page 43: ...40 5 6 ITEM C12 44658 01 UC4 JD JUNCTION CABLE ...
Page 44: ...41 5 7 ITEM C70 44658 08D UC4 ROLL BIAS VALVE CABLE DT ...
Page 45: ...42 5 8 ITEM C71 44647 CABLE UC3 SENSOR ROLL BIAS ...
Page 47: ...44 Figure 51 Cable C12 44658 01 BEFORE Modification ...
Page 48: ...45 Figure 52 Cable C12 44658 01 AFTER Modification ...