General Troubleshooting Information
IP560 Security Platform Installation Guide
101
Problem
Remote and local devices are not in the supported VC range of
the network interface card.
Solution
Use
ipsctl
to determine the VC range. Enter the following
command:
ipsctl ifphys:
logical interface
:max_rxlabel
Problem
Encapsulation is not set to LLC/SNAP.
Solution
Set encapsulation to LLC/SNAP. Consult your 1483 device
documentation.
Problem
The MTU size is not 1500.
Solution
The MTU size must be 1500. Nokia does not support larger MTU
sizes.
Appliance Not Receiving Power
Problem
Power cord is not properly plugged in.
Solution
Check cord. Make sure it is properly seated at both ends.
Problem
Power supply not providing power.
Solution
Check power source. If there is no power at the source, take
appropriate action such as inserting a new fuse or resetting circuit breaker.
Appliance Does Not Recognize New Memory Configuration
Problem
DIMMs are not properly seated in DIMM sockets.
Solution
Repeat memory installation procedures. Make sure DIMMs are
fully seated in sockets. Be sure DIMMs click into place.
Summary of Contents for IP560 - Hard Disk Drive Based
Page 1: ...Part No N450000014 Rev 001 Published December 2005 IP560 Security Platform Installation Guide ...
Page 4: ...4 IP560 Security Platform Installation Guide ...
Page 12: ...12 IP560 Security Platform Installation Guide ...
Page 36: ...1 Overview 36 IP560 Security Platform Installation Guide ...
Page 44: ...2 Installing the Nokia IP560 Appliance 44 IP560 Security Platform Installation Guide ...
Page 92: ...6 Using the Boot Manager 92 IP560 Security Platform Installation Guide ...
Page 108: ...7 Troubleshooting 108 IP560 Security Platform Installation Guide ...
Page 148: ...8 Replacing Other Components 148 IP560 Security Platform Installation Guide ...
Page 160: ...Index 160 IP560 Security Platform Installation Guide ...