55
Service Manual – SC500
04 - Control System
J6
Figure 42:
Two way vertical jumper
•
What is this for? The J6 Jumper is used to configure the Main machine controller for the EcoFlex option.
• What does it mean if it is jumped? The Main machine controller is set for no EcoFlex
• What does it mean if it is open? The Main machine controller is set for EcoFlex
• Is there a measurable voltage on either of the pins when not jumped? Yes 4 98v on pin near the LEDS on
the Main machine controller
J7 - 6 Ways
Measured machine did not have a wiring connector Measurements were taken at each pin on the Main
machine controller
Figure 43:
PIN
Color
Circuit Description
Measured
Comments
1
+24V power supply
24.6
2
+5V power supply
5.00
3
iButton input (CAN H channel)
4.98
4
Ext. operating time counter enable (CAN
L channel)
24.6
5
Power supply -
0.001
6
Machine on signal
23.68