04 - Control System
On-board Battery Charger Alarms
Alarm code
--------------------------
Description
Meaning
Condition
Effect
Service Suggestions
C1
-----------------------
CHARGER
COMMUNICAT.
Communication
problem between
the battery
charger and the
Main machine
controller.
No signal from battery
charger via gate J4.4 for
over 3 seconds.
The battery charger
is performing the
standard recharging
cycle for generic GEL/
AGM batteries.
Check the wiring between the battery charger
and the Main machine controller.
C2
-----------------------
BATTERY
OVERVOLTAGE
Battery
overvoltage.
Battery voltage over 32V. Battery charger block.
1.
Check the connections of the batteries and
the voltage of the installed batteries.
2.
Disconnect and reconnect the battery
charger.
C4
-----------------------
CHARGING TIME
I EXPIRED
Charging phase I
expired.
Battery excessively
discharged or at end of
life cycle.
Battery charger block. If the problem persists, replace the batteries.
C5
-----------------------
CHARGING TIME
II EXPIRED
Charging phase II
expired.
Battery excessively
discharged or at end of
life cycle.
Battery charger block. If the problem persists, replace the batteries.
C6
-----------------------
CHARGER
FAULT
Battery charger
internal short
circuit.
Battery charger internal
short circuit.
Battery charger block. Replace the battery charger.