04 - Control System
General alarms
Alarm on Main machine controller - FLASHING RED LEDS
Alarm code
--------------------------
Description
No.
Flashes Meaning
Condition
Effect
Service Suggestions
G3
-----------------------
MAIN FUSE
FAILURE
3
Blown F1 fuse.
Blown F1 fuse.
Function block.
F1 is a safety fuse primarily included to
prevent a short circuit or serious damage
to the Main machine controller causing
currents such as to melt cables and/or
cause smoke or fire. If F1 has blown, this is
usually indicative of serious damage to the
Main machine controller.
1.
Removing the cover should allow you to
understand the extent of the damage,
but the solution in any case should be to
replace the Main machine controller.
2.
Try replacing fuse F1 only if there is
no clear damage to the Main machine
controller and wiring.
3.
Ensure you tighten the fuse contacts
correctly.
Broken battery.
It could happen also if a battery is broken:
Check the battery voltage under load.
G4
-----------------------
BATTERY LOW
VOLTAGE
4
Undervoltage.
The battery voltage
remains below 18.4V for
over 10 seconds (for WET
CELL batteries, 19.6V for
GEL-AGM batteries).
Function block.
1.
Check the battery voltage under no-load
conditions and under load. Replace the
faulty battery/batteries if necessary.
2.
Recharge the batteries by performing a
complete charging cycle.
G5
-----------------------
BATTERY
OVERVOLTAGE
5
Excessive battery
voltage.
Battery voltage over 32V. Function block.
Check the voltage of the installed batteries
and that the terminals are correctly
tightened.
G6
-----------------------
HARDWARE
FAILURE
6
Serial
communication
error with the
User interface
controller.
No signal or error in
communications decoding
between the Main
machine controller (EB1)
and the Display controller
(EB2).
No block.
1.
Check the 5 cables from the 6-way
User interface controller connector to
connector J3 pins 1, 2, 3, 4.
2.
If there is continuity, the User interface
controller must be replaced.
G7
-----------------------
HARDWARE
FAILURE
7
General relay
fault.
Relay closes or closed at
start-up.
Function block.
Replace the Main machine controller.