113
Service Manual – SC500
24 - Electrical System
Maintenance and Adjustments
Setting the Installed Battery Type
Set the machine and the on-board battery charger (where fitted) on the basis of the type of battery to be
installed by modifying the BAT parameter as indicated
1 Insert the “Supervisor” key (grey) in place of the “User” key (blue) to access the main screen (Figure 4) of
the display
2 Press the One-Touch button
to continue to the machine settings screen (Figure 5)
Figure 4:
Figure 5:
3 Press the One-Touch button
until you reach the BAT parameter
MODIFIABLE PARAMETERS
Code
Description
Min. Value
Factory
Setting
Max. Value
BAT
Installed battery type
0
1
5
4 Press the “hare”
or “tortoise”
button to modify the value of the BAT parameter as per the
following table:
Code BAT
Value
Installed battery type
0
WET
Wet cell batteries
1
GEL / AGM
Generic GEL or AGM batteries
2
GEL DISCOVER
DISCOVER
®
brand GEL batteries
3
GEL OPTIMA
OPTIMA brand GEL batteries
4
GEL EXIDE
EXIDE
®
/SONNENSHINE brand GEL batteries
5
GEL FULLRIVER
FULLRIVER
®
brand GEL batteries
5 Press the brush release button
to confirm the chosen parameter and return to the main screen
(Figure 4)